authorGuoshuai Li <ligs@dtdream.com>2016-12-29 23:47:58 +0800
committerAndy Zhou <azhou@ovn.org>2016-12-30 15:22:53 -0800
commita38f532320936147e6831153828af5bcba2fba54 (patch)
treed33d5ca10c55e05a6a2981ad9b6aed85f6431e91 /datapath-windows/ovsext/Conntrack.c
parentd444a914fdbd4a5e1e41b81a3853deebb0da0db3 (diff)
downloadopenvswitch-a38f532320936147e6831153828af5bcba2fba54.tar.gz
OVN-HA: Fix data loss after OVNDB promotion
When master node shuts down, both VIP and OVNDB Master are expected to be moved over to the backup node. However, the VIP must be started after the OVNDB has been promoted. Otherwise, the database content can be whipped out, since the OVSDB running in the backup state can reconnect to the VIP that just moved over, thus removing the database content. See also: http://clusterlabs.org/doc/en-US/Pacemaker/1.1-pcs/html/ Pacemaker_Explained/s-resource-ordering.html Signed-off-by: Guoshuai Li <ligs@dtdream.com> Signed-off-by: Andy Zhou <azhou@ovn.org>