authorBruce Davie <bdavie@nicira.com>2013-11-01 10:53:23 -0700
committerBen Pfaff <blp@nicira.com>2013-11-01 13:54:15 -0700
commit255842d95365dbe1737bcc39b0daf47ce7f84c0d (patch)
tree1955e6a525810c82a1568a1db9cd7af8aa412658 /vtep/vtep.xml
parent9c0639a4637fa963ca8fa1dd87fb248f0a74b671 (diff)
downloadopenvswitch-255842d95365dbe1737bcc39b0daf47ce7f84c0d.tar.gz
vtep: add fault notifications to physical switch and ports
Add a "switch_fault" and "port_fault" column to the appropriate tables in the VTEP schema. Signed-off-by: Bruce Davie <bdavie@vmware.com> Signed-off-by: Ben Pfaff <blp@nicira.com>
Diffstat (limited to 'vtep/vtep.xml')
-rw-r--r--vtep/vtep.xml48
1 files changed, 46 insertions, 2 deletions
diff --git a/vtep/vtep.xml b/vtep/vtep.xml
index 39404790c..db8d4089e 100644
--- a/vtep/vtep.xml
+++ b/vtep/vtep.xml
@@ -274,6 +274,29 @@
banner.
</column>
</group>
+ <group title="Error Notification">
+ <p>
+ An entry in this column indicates to the NVC that this switch
+ has encountered a fault. The switch must clear this column
+ when the fault has been cleared.
+ </p>
+
+ <column name="switch_fault_status" key="mac_table_exhaustion">
+ Indicates that the switch has been unable to process MAC
+ entries requested by the NVC due to lack of table resources.
+ </column>
+
+ <column name="switch_fault_status" key="tunnel_exhaustion">
+ Indicates that the switch has been unable to create tunnels
+ requested by the NVC due to lack of resources.
+ </column>
+
+ <column name="switch_fault_status" key="unspecified_fault">
+ Indicates that an error has occurred in the switch but that no
+ more specific information is available.
+ </column>
+
+ </group>
</table>
<table name="Physical_Port" title="A port within a physical switch.">
@@ -306,6 +329,27 @@
An extended description for the port.
</column>
</group>
+ <group title="Error Notification">
+ <p>
+ An entry in this column indicates to the NVC that the physical port has
+ encountered a fault. The switch must clear this column when the errror
+ has been cleared.
+ </p>
+ <column name="port_fault_status" key="invalid_vlan_map">
+ <p>
+ Indicates that a VLAN-to-logical-switch mapping requested by
+ the controller could not be instantiated by the switch
+ because of a conflict with local configuration.
+ </p>
+ </column>
+ <column name="port_fault_status" key="unspecified_fault">
+ <p>
+ Indicates that an error has occurred on the port but that no
+ more specific information is available.
+ </p>
+ </column>
+ </group>
+
</table>
<table name="Logical_Binding_Stats" title="Statistics for a VLAN on a physical port bound to a logical network.">
@@ -453,7 +497,7 @@
</p>
<column name="MAC">
- A MAC address that has been learned by the NSC.
+ A MAC address that has been learned by the NVC.
</column>
<column name="logical_switch">
@@ -526,7 +570,7 @@
<column name="MAC">
<p>
- A MAC address that has been learned by the NSC.
+ A MAC address that has been learned by the NVC.
</p>
<p>
The keyword <code>unknown-dst</code> is used as a special