diff options
| author | Justin Pettit <jpettit@nicira.com> | 2011-04-26 19:58:19 -0700 |
|---|---|---|
| committer | Justin Pettit <jpettit@nicira.com> | 2011-05-05 00:45:27 -0700 |
| commit | daf2ebb30c2af023970172969366dea9ac787d7d (patch) | |
| tree | a70a04f47fbd778c7323993c5e094dbdb790fe95 /xenserver/openvswitch-xen.spec | |
| parent | d93ca2a0fdde23ef3e61bc34a9809f6c38239c45 (diff) | |
| download | openvswitch-daf2ebb30c2af023970172969366dea9ac787d7d.tar.gz | |
xenserver: Use xe-switch-network-stack in RPM spec file.
The proper way to switch the networking back-end is to use the
"xe-switch-network-stack" command rather than directly modifying
"/etc/xensource/network.conf". Use that method in the spec file.
Diffstat (limited to 'xenserver/openvswitch-xen.spec')
| -rw-r--r-- | xenserver/openvswitch-xen.spec | 14 |
1 files changed, 2 insertions, 12 deletions
diff --git a/xenserver/openvswitch-xen.spec b/xenserver/openvswitch-xen.spec index 97bf99ca0..de702addb 100644 --- a/xenserver/openvswitch-xen.spec +++ b/xenserver/openvswitch-xen.spec @@ -226,12 +226,7 @@ done if [ "$1" = "1" ]; then # $1 = 2 for upgrade # Configure system to use Open vSwitch - echo vswitch > /etc/xensource/network.conf - - printf "\nYou MUST reboot the server NOW to complete the change to\n" - printf "Open vSwitch. Attempts to modify networking on the server\n" - printf "or any hosted VM will fail until after the reboot and could\n" - printf "leave the server in a state requiring manual recovery.\n\n" + xe-switch-network-backend vswitch else mode=$(cat /etc/xensource/network.conf) @@ -310,12 +305,7 @@ if [ "$1" = "0" ]; then # $1 = 1 for upgrade rmdir -p /usr/lib/openvswitch/xs-saved 2>/dev/null # Configure system to use bridge - echo bridge > /etc/xensource/network.conf - - printf "\nYou MUST reboot the server now to complete the change to\n" - printf "standard Xen networking. Attempts to modify networking on the\n" - printf "server or any hosted VM will fail until after the reboot and\n" - printf "could leave the server in a state requiring manual recovery.\n\n" + xe-switch-network-backend bridge fi %files |