1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
|
..
Licensed under the Apache License, Version 2.0 (the "License"); you may
not use this file except in compliance with the License. You may obtain
a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
License for the specific language governing permissions and limitations
under the License.
Convention for heading levels in Open vSwitch documentation:
======= Heading 0 (reserved for the title in a document)
------- Heading 1
~~~~~~~ Heading 2
+++++++ Heading 3
''''''' Heading 4
Avoid deeper levels because they do not render well.
============================
Using Open vSwitch with DPDK
============================
This document describes how to use Open vSwitch with DPDK datapath.
.. important::
Using the DPDK datapath requires building OVS with DPDK support. Refer to
:doc:`/intro/install/dpdk` for more information.
Ports and Bridges
-----------------
ovs-vsctl can be used to set up bridges and other Open vSwitch features.
Bridges should be created with a ``datapath_type=netdev``::
$ ovs-vsctl add-br br0 -- set bridge br0 datapath_type=netdev
ovs-vsctl can also be used to add DPDK devices. ovs-vswitchd should print the
number of dpdk devices found in the log file::
$ ovs-vsctl add-port br0 dpdk-p0 -- set Interface dpdk-p0 type=dpdk \
options:dpdk-devargs=0000:01:00.0
$ ovs-vsctl add-port br0 dpdk-p1 -- set Interface dpdk-p1 type=dpdk \
options:dpdk-devargs=0000:01:00.1
After the DPDK ports get added to switch, a polling thread continuously polls
DPDK devices and consumes 100% of the core, as can be checked from ``top`` and
``ps`` commands::
$ top -H
$ ps -eLo pid,psr,comm | grep pmd
Creating bonds of DPDK interfaces is slightly different to creating bonds of
system interfaces. For DPDK, the interface type and devargs must be explicitly
set. For example::
$ ovs-vsctl add-bond br0 dpdkbond p0 p1 \
-- set Interface p0 type=dpdk options:dpdk-devargs=0000:01:00.0 \
-- set Interface p1 type=dpdk options:dpdk-devargs=0000:01:00.1
To stop ovs-vswitchd & delete bridge, run::
$ ovs-appctl -t ovs-vswitchd exit
$ ovs-appctl -t ovsdb-server exit
$ ovs-vsctl del-br br0
PMD Thread Statistics
---------------------
To show current stats::
$ ovs-appctl dpif-netdev/pmd-stats-show
To clear previous stats::
$ ovs-appctl dpif-netdev/pmd-stats-clear
Port/RXQ Assigment to PMD Threads
---------------------------------
To show port/rxq assignment::
$ ovs-appctl dpif-netdev/pmd-rxq-show
To change default rxq assignment to pmd threads, rxqs may be manually pinned to
desired cores using::
$ ovs-vsctl set Interface <iface> \
other_config:pmd-rxq-affinity=<rxq-affinity-list>
where:
- ``<rxq-affinity-list>`` is a CSV list of ``<queue-id>:<core-id>`` values
For example::
$ ovs-vsctl set interface dpdk-p0 options:n_rxq=4 \
other_config:pmd-rxq-affinity="0:3,1:7,3:8"
This will ensure:
- Queue #0 pinned to core 3
- Queue #1 pinned to core 7
- Queue #2 not pinned
- Queue #3 pinned to core 8
After that PMD threads on cores where RX queues was pinned will become
``isolated``. This means that this thread will poll only pinned RX queues.
.. warning::
If there are no ``non-isolated`` PMD threads, ``non-pinned`` RX queues will
not be polled. Also, if provided ``core_id`` is not available (ex. this
``core_id`` not in ``pmd-cpu-mask``), RX queue will not be polled by any PMD
thread.
QoS
---
Assuming you have a vhost-user port transmitting traffic consisting of packets
of size 64 bytes, the following command would limit the egress transmission
rate of the port to ~1,000,000 packets per second::
$ ovs-vsctl set port vhost-user0 qos=@newqos -- \
--id=@newqos create qos type=egress-policer other-config:cir=46000000 \
other-config:cbs=2048`
To examine the QoS configuration of the port, run::
$ ovs-appctl -t ovs-vswitchd qos/show vhost-user0
To clear the QoS configuration from the port and ovsdb, run::
$ ovs-vsctl destroy QoS vhost-user0 -- clear Port vhost-user0 qos
Refer to vswitch.xml for more details on egress-policer.
Rate Limiting
--------------
Here is an example on Ingress Policing usage. Assuming you have a vhost-user
port receiving traffic consisting of packets of size 64 bytes, the following
command would limit the reception rate of the port to ~1,000,000 packets per
second::
$ ovs-vsctl set interface vhost-user0 ingress_policing_rate=368000 \
ingress_policing_burst=1000`
To examine the ingress policer configuration of the port::
$ ovs-vsctl list interface vhost-user0
To clear the ingress policer configuration from the port::
$ ovs-vsctl set interface vhost-user0 ingress_policing_rate=0
Refer to vswitch.xml for more details on ingress-policer.
Flow Control
------------
Flow control can be enabled only on DPDK physical ports. To enable flow control
support at tx side while adding a port, run::
$ ovs-vsctl add-port br0 dpdk-p0 -- set Interface dpdk-p0 type=dpdk \
options:dpdk-devargs=0000:01:00.0 options:tx-flow-ctrl=true
Similarly, to enable rx flow control, run::
$ ovs-vsctl add-port br0 dpdk-p0 -- set Interface dpdk-p0 type=dpdk \
options:dpdk-devargs=0000:01:00.0 options:rx-flow-ctrl=true
To enable flow control auto-negotiation, run::
$ ovs-vsctl add-port br0 dpdk-p0 -- set Interface dpdk-p0 type=dpdk \
options:dpdk-devargs=0000:01:00.0 options:flow-ctrl-autoneg=true
To turn ON the tx flow control at run time for an existing port, run::
$ ovs-vsctl set Interface dpdk-p0 options:tx-flow-ctrl=true
The flow control parameters can be turned off by setting ``false`` to the
respective parameter. To disable the flow control at tx side, run::
$ ovs-vsctl set Interface dpdk-p0 options:tx-flow-ctrl=false
pdump
-----
pdump allows you to listen on DPDK ports and view the traffic that is passing
on them. To use this utility, one must have libpcap installed on the system.
Furthermore, DPDK must be built with ``CONFIG_RTE_LIBRTE_PDUMP=y`` and
``CONFIG_RTE_LIBRTE_PMD_PCAP=y``.
.. warning::
A performance decrease is expected when using a monitoring application like
the DPDK pdump app.
To use pdump, simply launch OVS as usual, then navigate to the ``app/pdump``
directory in DPDK, ``make`` the application and run like so::
$ sudo ./build/app/dpdk-pdump -- \
--pdump port=0,queue=0,rx-dev=/tmp/pkts.pcap \
--server-socket-path=/usr/local/var/run/openvswitch
The above command captures traffic received on queue 0 of port 0 and stores it
in ``/tmp/pkts.pcap``. Other combinations of port numbers, queues numbers and
pcap locations are of course also available to use. For example, to capture all
packets that traverse port 0 in a single pcap file::
$ sudo ./build/app/dpdk-pdump -- \
--pdump 'port=0,queue=*,rx-dev=/tmp/pkts.pcap,tx-dev=/tmp/pkts.pcap' \
--server-socket-path=/usr/local/var/run/openvswitch
``server-socket-path`` must be set to the value of ``ovs_rundir()`` which
typically resolves to ``/usr/local/var/run/openvswitch``.
Many tools are available to view the contents of the pcap file. Once example is
tcpdump. Issue the following command to view the contents of ``pkts.pcap``::
$ tcpdump -r pkts.pcap
More information on the pdump app and its usage can be found in the `DPDK docs
<http://dpdk.org/doc/guides/tools/pdump.html>`__.
Jumbo Frames
------------
By default, DPDK ports are configured with standard Ethernet MTU (1500B). To
enable Jumbo Frames support for a DPDK port, change the Interface's
``mtu_request`` attribute to a sufficiently large value. For example, to add a
DPDK Phy port with MTU of 9000::
$ ovs-vsctl add-port br0 dpdk-p0 -- set Interface dpdk-p0 type=dpdk \
options:dpdk-devargs=0000:01:00.0 mtu_request=9000
Similarly, to change the MTU of an existing port to 6200::
$ ovs-vsctl set Interface dpdk-p0 mtu_request=6200
Some additional configuration is needed to take advantage of jumbo frames with
vHost ports:
1. *mergeable buffers* must be enabled for vHost ports, as demonstrated in the
QEMU command line snippet below::
-netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
-device virtio-net-pci,mac=00:00:00:00:00:01,netdev=mynet1,mrg_rxbuf=on
2. Where virtio devices are bound to the Linux kernel driver in a guest
environment (i.e. interfaces are not bound to an in-guest DPDK driver), the
MTU of those logical network interfaces must also be increased to a
sufficiently large value. This avoids segmentation of Jumbo Frames received
in the guest. Note that 'MTU' refers to the length of the IP packet only,
and not that of the entire frame.
To calculate the exact MTU of a standard IPv4 frame, subtract the L2 header
and CRC lengths (i.e. 18B) from the max supported frame size. So, to set
the MTU for a 9018B Jumbo Frame::
$ ifconfig eth1 mtu 9000
When Jumbo Frames are enabled, the size of a DPDK port's mbuf segments are
increased, such that a full Jumbo Frame of a specific size may be accommodated
within a single mbuf segment.
Jumbo frame support has been validated against 9728B frames, which is the
largest frame size supported by Fortville NIC using the DPDK i40e driver, but
larger frames and other DPDK NIC drivers may be supported. These cases are
common for use cases involving East-West traffic only.
Rx Checksum Offload
-------------------
By default, DPDK physical ports are enabled with Rx checksum offload. Rx
checksum offload can be configured on a DPDK physical port either when adding
or at run time.
To disable Rx checksum offload when adding a DPDK port dpdk-p0::
$ ovs-vsctl add-port br0 dpdk-p0 -- set Interface dpdk-p0 type=dpdk \
options:dpdk-devargs=0000:01:00.0 options:rx-checksum-offload=false
Similarly to disable the Rx checksum offloading on a existing DPDK port dpdk-p0::
$ ovs-vsctl set Interface dpdk-p0 options:rx-checksum-offload=false
Rx checksum offload can offer performance improvement only for tunneling
traffic in OVS-DPDK because the checksum validation of tunnel packets is
offloaded to the NIC. Also enabling Rx checksum may slightly reduce the
performance of non-tunnel traffic, specifically for smaller size packet.
DPDK vectorization is disabled when checksum offloading is configured on DPDK
physical ports which in turn effects the non-tunnel traffic performance.
So it is advised to turn off the Rx checksum offload for non-tunnel traffic use
cases to achieve the best performance.
.. _extended-statistics:
Extended Statistics
-------------------
DPDK Extended Statistics API allows PMD to expose unique set of statistics.
The Extended statistics are implemented and supported only for DPDK physical
and vHost ports.
To enable statistics, you have to enable OpenFlow 1.4 support for OVS.
Configure bridge br0 to support OpenFlow version 1.4::
$ ovs-vsctl set bridge br0 datapath_type=netdev \
protocols=OpenFlow10,OpenFlow11,OpenFlow12,OpenFlow13,OpenFlow14
Check the OVSDB protocols column in the bridge table if OpenFlow 1.4 support
is enabled for OVS::
$ ovsdb-client dump Bridge protocols
Query the port statistics by explicitly specifying -O OpenFlow14 option::
$ ovs-ofctl -O OpenFlow14 dump-ports br0
Note: vHost ports supports only partial statistics. RX packet size based
counter are only supported and doesn't include TX packet size counters.
.. _port-hotplug:
Port Hotplug
------------
OVS supports port hotplugging, allowing the use of ports that were not bound
to DPDK when vswitchd was started.
In order to attach a port, it has to be bound to DPDK using the
``dpdk_nic_bind.py`` script::
$ $DPDK_DIR/tools/dpdk_nic_bind.py --bind=igb_uio 0000:01:00.0
Then it can be attached to OVS::
$ ovs-vsctl add-port br0 dpdkx -- set Interface dpdkx type=dpdk \
options:dpdk-devargs=0000:01:00.0
It is also possible to detach a port from ovs, the user has to remove the
port using the del-port command, then it can be detached using::
$ ovs-appctl netdev-dpdk/detach 0000:01:00.0
This feature is not supported with VFIO and does not work with some NICs.
For more information please refer to the `DPDK Port Hotplug Framework
<http://dpdk.org/doc/guides/prog_guide/port_hotplug_framework.html#hotplug>`__.
.. _vdev-support:
Vdev Support
------------
DPDK provides drivers for both physical and virtual devices. Physical DPDK
devices are added to OVS by specifying a valid PCI address in 'dpdk-devargs'.
Virtual DPDK devices which do not have PCI addresses can be added using a
different format for 'dpdk-devargs'.
Typically, the format expected is 'eth_<driver_name><x>' where 'x' is a
number between 0 and RTE_MAX_ETHPORTS -1 (31).
For example to add a dpdk port that uses the 'null' DPDK PMD driver::
$ ovs-vsctl add-port br0 null0 -- set Interface null0 type=dpdk \
options:dpdk-devargs=eth_null0
Similarly, to add a dpdk port that uses the 'af_packet' DPDK PMD driver::
$ ovs-vsctl add-port br0 myeth0 -- set Interface myeth0 type=dpdk \
options:dpdk-devargs=eth_af_packet0,iface=eth0
More information on the different types of virtual DPDK PMDs can be found in
the `DPDK documentation
<http://dpdk.org/doc/guides/nics/overview.html>`__.
Note: Not all DPDK virtual PMD drivers have been tested and verified to work.
EMC Insertion Probability
-------------------------
By default 1 in every 100 flows are inserted into the Exact Match Cache (EMC).
It is possible to change this insertion probability by setting the
``emc-insert-inv-prob`` option::
$ ovs-vsctl --no-wait set Open_vSwitch . other_config:emc-insert-inv-prob=N
where:
``N``
is a positive integer representing the inverse probability of insertion ie.
on average 1 in every N packets with a unique flow will generate an EMC
insertion.
If ``N`` is set to 1, an insertion will be performed for every flow. If set to
0, no insertions will be performed and the EMC will effectively be disabled.
For more information on the EMC refer to :doc:`/intro/install/dpdk` .
.. _dpdk-ovs-in-guest:
OVS with DPDK Inside VMs
------------------------
Additional configuration is required if you want to run ovs-vswitchd with DPDK
backend inside a QEMU virtual machine. ovs-vswitchd creates separate DPDK TX
queues for each CPU core available. This operation fails inside QEMU virtual
machine because, by default, VirtIO NIC provided to the guest is configured to
support only single TX queue and single RX queue. To change this behavior, you
need to turn on ``mq`` (multiqueue) property of all ``virtio-net-pci`` devices
emulated by QEMU and used by DPDK. You may do it manually (by changing QEMU
command line) or, if you use Libvirt, by adding the following string to
``<interface>`` sections of all network devices used by DPDK::
<driver name='vhost' queues='N'/>
where:
``N``
determines how many queues can be used by the guest.
This requires QEMU >= 2.2.
.. _dpdk-phy-phy:
PHY-PHY
-------
Add a userspace bridge and two ``dpdk`` (PHY) ports::
# Add userspace bridge
$ ovs-vsctl add-br br0 -- set bridge br0 datapath_type=netdev
# Add two dpdk ports
$ ovs-vsctl add-port br0 phy0 -- set Interface phy0 type=dpdk \
options:dpdk-devargs=0000:01:00.0 ofport_request=1
$ ovs-vsctl add-port br0 phy1 -- set Interface phy1 type=dpdk
options:dpdk-devargs=0000:01:00.1 ofport_request=2
Add test flows to forward packets betwen DPDK port 0 and port 1::
# Clear current flows
$ ovs-ofctl del-flows br0
# Add flows between port 1 (phy0) to port 2 (phy1)
$ ovs-ofctl add-flow br0 in_port=1,action=output:2
$ ovs-ofctl add-flow br0 in_port=2,action=output:1
Transmit traffic into either port. You should see it returned via the other.
.. _dpdk-vhost-loopback:
PHY-VM-PHY (vHost Loopback)
---------------------------
Add a userspace bridge, two ``dpdk`` (PHY) ports, and two ``dpdkvhostuser``
ports::
# Add userspace bridge
$ ovs-vsctl add-br br0 -- set bridge br0 datapath_type=netdev
# Add two dpdk ports
$ ovs-vsctl add-port br0 phy0 -- set Interface phy0 type=dpdk \
options:dpdk-devargs=0000:01:00.0 ofport_request=1
$ ovs-vsctl add-port br0 phy1 -- set Interface phy1 type=dpdk
options:dpdk-devargs=0000:01:00.1 ofport_request=2
# Add two dpdkvhostuser ports
$ ovs-vsctl add-port br0 dpdkvhostuser0 \
-- set Interface dpdkvhostuser0 type=dpdkvhostuser ofport_request=3
$ ovs-vsctl add-port br0 dpdkvhostuser1 \
-- set Interface dpdkvhostuser1 type=dpdkvhostuser ofport_request=4
Add test flows to forward packets betwen DPDK devices and VM ports::
# Clear current flows
$ ovs-ofctl del-flows br0
# Add flows
$ ovs-ofctl add-flow br0 in_port=1,action=output:3
$ ovs-ofctl add-flow br0 in_port=3,action=output:1
$ ovs-ofctl add-flow br0 in_port=4,action=output:2
$ ovs-ofctl add-flow br0 in_port=2,action=output:4
# Dump flows
$ ovs-ofctl dump-flows br0
Create a VM using the following configuration:
+----------------------+--------+-----------------+
| configuration | values | comments |
+----------------------+--------+-----------------+
| qemu version | 2.2.0 | n/a |
| qemu thread affinity | core 5 | taskset 0x20 |
| memory | 4GB | n/a |
| cores | 2 | n/a |
| Qcow2 image | CentOS7| n/a |
| mrg_rxbuf | off | n/a |
+----------------------+--------+-----------------+
You can do this directly with QEMU via the ``qemu-system-x86_64`` application::
$ export VM_NAME=vhost-vm
$ export GUEST_MEM=3072M
$ export QCOW2_IMAGE=/root/CentOS7_x86_64.qcow2
$ export VHOST_SOCK_DIR=/usr/local/var/run/openvswitch
$ taskset 0x20 qemu-system-x86_64 -name $VM_NAME -cpu host -enable-kvm \
-m $GUEST_MEM -drive file=$QCOW2_IMAGE --nographic -snapshot \
-numa node,memdev=mem -mem-prealloc -smp sockets=1,cores=2 \
-object memory-backend-file,id=mem,size=$GUEST_MEM,mem-path=/dev/hugepages,share=on \
-chardev socket,id=char0,path=$VHOST_SOCK_DIR/dpdkvhostuser0 \
-netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
-device virtio-net-pci,mac=00:00:00:00:00:01,netdev=mynet1,mrg_rxbuf=off \
-chardev socket,id=char1,path=$VHOST_SOCK_DIR/dpdkvhostuser1 \
-netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce \
-device virtio-net-pci,mac=00:00:00:00:00:02,netdev=mynet2,mrg_rxbuf=off
For a explanation of this command, along with alternative approaches such as
booting the VM via libvirt, refer to :doc:`/topics/dpdk/vhost-user`.
Once the guest is configured and booted, configure DPDK packet forwarding
within the guest. To accomplish this, build the ``testpmd`` application as
described in :ref:`dpdk-testpmd`. Once compiled, run the application::
$ cd $DPDK_DIR/app/test-pmd;
$ ./testpmd -c 0x3 -n 4 --socket-mem 1024 -- \
--burst=64 -i --txqflags=0xf00 --disable-hw-vlan
$ set fwd mac retry
$ start
When you finish testing, bind the vNICs back to kernel::
$ $DPDK_DIR/tools/dpdk-devbind.py --bind=virtio-pci 0000:00:03.0
$ $DPDK_DIR/tools/dpdk-devbind.py --bind=virtio-pci 0000:00:04.0
.. note::
Valid PCI IDs must be passed in above example. The PCI IDs can be retrieved
like so::
$ $DPDK_DIR/tools/dpdk-devbind.py --status
More information on the dpdkvhostuser ports can be found in
:doc:`/topics/dpdk/vhost-user`.
PHY-VM-PHY (vHost Loopback) (Kernel Forwarding)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
:ref:`dpdk-vhost-loopback` details steps for PHY-VM-PHY loopback
testcase and packet forwarding using DPDK testpmd application in the Guest VM.
For users wishing to do packet forwarding using kernel stack below, you need to
run the below commands on the guest::
$ ifconfig eth1 1.1.1.2/24
$ ifconfig eth2 1.1.2.2/24
$ systemctl stop firewalld.service
$ systemctl stop iptables.service
$ sysctl -w net.ipv4.ip_forward=1
$ sysctl -w net.ipv4.conf.all.rp_filter=0
$ sysctl -w net.ipv4.conf.eth1.rp_filter=0
$ sysctl -w net.ipv4.conf.eth2.rp_filter=0
$ route add -net 1.1.2.0/24 eth2
$ route add -net 1.1.1.0/24 eth1
$ arp -s 1.1.2.99 DE:AD:BE:EF:CA:FE
$ arp -s 1.1.1.99 DE:AD:BE:EF:CA:EE
PHY-VM-PHY (vHost Multiqueue)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
vHost Multiqueue functionality can also be validated using the PHY-VM-PHY
configuration. To begin, follow the steps described in :ref:`dpdk-phy-phy` to
create and initialize the database, start ovs-vswitchd and add ``dpdk``-type
devices to bridge ``br0``. Once complete, follow the below steps:
1. Configure PMD and RXQs.
For example, set the number of dpdk port rx queues to at least 2 The number
of rx queues at vhost-user interface gets automatically configured after
virtio device connection and doesn't need manual configuration::
$ ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=0xc
$ ovs-vsctl set Interface phy0 options:n_rxq=2
$ ovs-vsctl set Interface phy1 options:n_rxq=2
2. Instantiate Guest VM using QEMU cmdline
We must configure with appropriate software versions to ensure this feature
is supported.
.. list-table:: Recommended BIOS Settings
:header-rows: 1
* - Setting
- Value
* - QEMU version
- 2.5.0
* - QEMU thread affinity
- 2 cores (taskset 0x30)
* - Memory
- 4 GB
* - Cores
- 2
* - Distro
- Fedora 22
* - Multiqueue
- Enabled
To do this, instantiate the guest as follows::
$ export VM_NAME=vhost-vm
$ export GUEST_MEM=4096M
$ export QCOW2_IMAGE=/root/Fedora22_x86_64.qcow2
$ export VHOST_SOCK_DIR=/usr/local/var/run/openvswitch
$ taskset 0x30 qemu-system-x86_64 -cpu host -smp 2,cores=2 -m 4096M \
-drive file=$QCOW2_IMAGE --enable-kvm -name $VM_NAME \
-nographic -numa node,memdev=mem -mem-prealloc \
-object memory-backend-file,id=mem,size=$GUEST_MEM,mem-path=/dev/hugepages,share=on \
-chardev socket,id=char1,path=$VHOST_SOCK_DIR/dpdkvhostuser0 \
-netdev type=vhost-user,id=mynet1,chardev=char1,vhostforce,queues=2 \
-device virtio-net-pci,mac=00:00:00:00:00:01,netdev=mynet1,mq=on,vectors=6 \
-chardev socket,id=char2,path=$VHOST_SOCK_DIR/dpdkvhostuser1 \
-netdev type=vhost-user,id=mynet2,chardev=char2,vhostforce,queues=2 \
-device virtio-net-pci,mac=00:00:00:00:00:02,netdev=mynet2,mq=on,vectors=6
.. note::
Queue value above should match the queues configured in OVS, The vector
value should be set to "number of queues x 2 + 2"
3. Configure the guest interface
Assuming there are 2 interfaces in the guest named eth0, eth1 check the
channel configuration and set the number of combined channels to 2 for
virtio devices::
$ ethtool -l eth0
$ ethtool -L eth0 combined 2
$ ethtool -L eth1 combined 2
More information can be found in vHost walkthrough section.
4. Configure kernel packet forwarding
Configure IP and enable interfaces::
$ ifconfig eth0 5.5.5.1/24 up
$ ifconfig eth1 90.90.90.1/24 up
Configure IP forwarding and add route entries::
$ sysctl -w net.ipv4.ip_forward=1
$ sysctl -w net.ipv4.conf.all.rp_filter=0
$ sysctl -w net.ipv4.conf.eth0.rp_filter=0
$ sysctl -w net.ipv4.conf.eth1.rp_filter=0
$ ip route add 2.1.1.0/24 dev eth1
$ route add default gw 2.1.1.2 eth1
$ route add default gw 90.90.90.90 eth1
$ arp -s 90.90.90.90 DE:AD:BE:EF:CA:FE
$ arp -s 2.1.1.2 DE:AD:BE:EF:CA:FA
Check traffic on multiple queues::
$ cat /proc/interrupts | grep virtio
|