1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
|
Using Open vSwitch with DPDK
============================
Open vSwitch can use Intel(R) DPDK lib to operate entirely in
userspace. This file explains how to install and use Open vSwitch in
such a mode.
The DPDK support of Open vSwitch is considered experimental.
It has not been thoroughly tested.
This version of Open vSwitch should be built manually with `configure`
and `make`.
OVS needs a system with 1GB hugepages support.
Building and Installing:
------------------------
Required: DPDK 2.2
Optional (if building with vhost-cuse): `fuse`, `fuse-devel` (`libfuse-dev`
on Debian/Ubuntu)
1. Configure build & install DPDK:
1. Set `$DPDK_DIR`
```
export DPDK_DIR=/usr/src/dpdk-2.2
cd $DPDK_DIR
```
2. Update `config/common_linuxapp` so that DPDK generate single lib file.
(modification also required for IVSHMEM build)
`CONFIG_RTE_BUILD_COMBINE_LIBS=y`
Then run `make install` to build and install the library.
For default install without IVSHMEM:
`make install T=x86_64-native-linuxapp-gcc DESTDIR=install`
To include IVSHMEM (shared memory):
`make install T=x86_64-ivshmem-linuxapp-gcc DESTDIR=install`
For further details refer to http://dpdk.org/
2. Configure & build the Linux kernel:
Refer to intel-dpdk-getting-started-guide.pdf for understanding
DPDK kernel requirement.
3. Configure & build OVS:
* Non IVSHMEM:
`export DPDK_BUILD=$DPDK_DIR/x86_64-native-linuxapp-gcc/`
* IVSHMEM:
`export DPDK_BUILD=$DPDK_DIR/x86_64-ivshmem-linuxapp-gcc/`
```
cd $(OVS_DIR)/
./boot.sh
./configure --with-dpdk=$DPDK_BUILD [CFLAGS="-g -O2 -Wno-cast-align"]
make
```
Note: 'clang' users may specify the '-Wno-cast-align' flag to suppress DPDK cast-align warnings.
To have better performance one can enable aggressive compiler optimizations and
use the special instructions(popcnt, crc32) that may not be available on all
machines. Instead of typing `make`, type:
`make CFLAGS='-O3 -march=native'`
Refer to [INSTALL.userspace.md] for general requirements of building userspace OVS.
Using the DPDK with ovs-vswitchd:
---------------------------------
1. Setup system boot
Add the following options to the kernel bootline:
`default_hugepagesz=1GB hugepagesz=1G hugepages=1`
2. Setup DPDK devices:
DPDK devices can be setup using either the VFIO (for DPDK 1.7+) or UIO
modules. UIO requires inserting an out of tree driver igb_uio.ko that is
available in DPDK. Setup for both methods are described below.
* UIO:
1. insert uio.ko: `modprobe uio`
2. insert igb_uio.ko: `insmod $DPDK_BUILD/kmod/igb_uio.ko`
3. Bind network device to igb_uio:
`$DPDK_DIR/tools/dpdk_nic_bind.py --bind=igb_uio eth1`
* VFIO:
VFIO needs to be supported in the kernel and the BIOS. More information
can be found in the [DPDK Linux GSG].
1. Insert vfio-pci.ko: `modprobe vfio-pci`
2. Set correct permissions on vfio device: `sudo /usr/bin/chmod a+x /dev/vfio`
and: `sudo /usr/bin/chmod 0666 /dev/vfio/*`
3. Bind network device to vfio-pci:
`$DPDK_DIR/tools/dpdk_nic_bind.py --bind=vfio-pci eth1`
3. Mount the hugetable filesystem
`mount -t hugetlbfs -o pagesize=1G none /dev/hugepages`
Ref to http://www.dpdk.org/doc/quick-start for verifying DPDK setup.
4. Follow the instructions in [INSTALL.md] to install only the
userspace daemons and utilities (via 'make install').
1. First time only db creation (or clearing):
```
mkdir -p /usr/local/etc/openvswitch
mkdir -p /usr/local/var/run/openvswitch
rm /usr/local/etc/openvswitch/conf.db
ovsdb-tool create /usr/local/etc/openvswitch/conf.db \
/usr/local/share/openvswitch/vswitch.ovsschema
```
2. Start ovsdb-server
```
ovsdb-server --remote=punix:/usr/local/var/run/openvswitch/db.sock \
--remote=db:Open_vSwitch,Open_vSwitch,manager_options \
--private-key=db:Open_vSwitch,SSL,private_key \
--certificate=Open_vSwitch,SSL,certificate \
--bootstrap-ca-cert=db:Open_vSwitch,SSL,ca_cert --pidfile --detach
```
3. First time after db creation, initialize:
```
ovs-vsctl --no-wait init
```
5. Start vswitchd:
DPDK configuration arguments can be passed to vswitchd via `--dpdk`
argument. This needs to be first argument passed to vswitchd process.
dpdk arg -c is ignored by ovs-dpdk, but it is a required parameter
for dpdk initialization.
```
export DB_SOCK=/usr/local/var/run/openvswitch/db.sock
ovs-vswitchd --dpdk -c 0x1 -n 4 -- unix:$DB_SOCK --pidfile --detach
```
If allocated more than one GB hugepage (as for IVSHMEM), set amount and
use NUMA node 0 memory:
```
ovs-vswitchd --dpdk -c 0x1 -n 4 --socket-mem 1024,0 \
-- unix:$DB_SOCK --pidfile --detach
```
6. Add bridge & ports
To use ovs-vswitchd with DPDK, create a bridge with datapath_type
"netdev" in the configuration database. For example:
`ovs-vsctl add-br br0 -- set bridge br0 datapath_type=netdev`
Now you can add dpdk devices. OVS expects DPDK device names to start with
"dpdk" and end with a portid. vswitchd should print (in the log file) the
number of dpdk devices found.
```
ovs-vsctl add-port br0 dpdk0 -- set Interface dpdk0 type=dpdk
ovs-vsctl add-port br0 dpdk1 -- set Interface dpdk1 type=dpdk
```
Once first DPDK port is added to vswitchd, it creates a Polling thread and
polls dpdk device in continuous loop. Therefore CPU utilization
for that thread is always 100%.
Note: creating bonds of DPDK interfaces is slightly different to creating
bonds of system interfaces. For DPDK, the interface type must be explicitly
set, for example:
```
ovs-vsctl add-bond br0 dpdkbond dpdk0 dpdk1 -- set Interface dpdk0 type=dpdk -- set Interface dpdk1 type=dpdk
```
7. Add test flows
Test flow script across NICs (assuming ovs in /usr/src/ovs):
Execute script:
```
#! /bin/sh
# Move to command directory
cd /usr/src/ovs/utilities/
# Clear current flows
./ovs-ofctl del-flows br0
# Add flows between port 1 (dpdk0) to port 2 (dpdk1)
./ovs-ofctl add-flow br0 in_port=1,action=output:2
./ovs-ofctl add-flow br0 in_port=2,action=output:1
```
8. QoS usage example
Assuming you have a vhost-user port transmitting traffic consisting of
packets of size 64 bytes, the following command would limit the egress
transmission rate of the port to ~1,000,000 packets per second:
`ovs-vsctl set port vhost-user0 qos=@newqos -- --id=@newqos create qos
type=egress-policer other-config:cir=46000000 other-config:cbs=2048`
To examine the QoS configuration of the port:
`ovs-appctl -t ovs-vswitchd qos/show vhost-user0`
To clear the QoS configuration from the port and ovsdb use the following:
`ovs-vsctl destroy QoS vhost-user0 -- clear Port vhost-user0 qos`
For more details regarding egress-policer parameters please refer to the
vswitch.xml.
Performance Tuning:
-------------------
1. PMD affinitization
A poll mode driver (pmd) thread handles the I/O of all DPDK
interfaces assigned to it. A pmd thread will busy loop through
the assigned port/rxq's polling for packets, switch the packets
and send to a tx port if required. Typically, it is found that
a pmd thread is CPU bound, meaning that the greater the CPU
occupancy the pmd thread can get, the better the performance. To
that end, it is good practice to ensure that a pmd thread has as
many cycles on a core available to it as possible. This can be
achieved by affinitizing the pmd thread with a core that has no
other workload. See section 7 below for a description of how to
isolate cores for this purpose also.
The following command can be used to specify the affinity of the
pmd thread(s).
`ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=<hex string>`
By setting a bit in the mask, a pmd thread is created and pinned
to the corresponding CPU core. e.g. to run a pmd thread on core 1
`ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=2`
For more information, please refer to the Open_vSwitch TABLE section in
`man ovs-vswitchd.conf.db`
Note, that a pmd thread on a NUMA node is only created if there is
at least one DPDK interface from that NUMA node added to OVS.
2. Multiple poll mode driver threads
With pmd multi-threading support, OVS creates one pmd thread
for each NUMA node by default. However, it can be seen that in cases
where there are multiple ports/rxq's producing traffic, performance
can be improved by creating multiple pmd threads running on separate
cores. These pmd threads can then share the workload by each being
responsible for different ports/rxq's. Assignment of ports/rxq's to
pmd threads is done automatically.
The following command can be used to specify the affinity of the
pmd threads.
`ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=<hex string>`
A set bit in the mask means a pmd thread is created and pinned
to the corresponding CPU core. e.g. to run pmd threads on core 1 and 2
`ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=6`
For more information, please refer to the Open_vSwitch TABLE section in
`man ovs-vswitchd.conf.db`
For example, when using dpdk and dpdkvhostuser ports in a bi-directional
VM loopback as shown below, spreading the workload over 2 or 4 pmd
threads shows significant improvements as there will be more total CPU
occupancy available.
NIC port0 <-> OVS <-> VM <-> OVS <-> NIC port 1
The following command can be used to confirm that the port/rxq assignment
to pmd threads is as required:
`ovs-appctl dpif-netdev/pmd-rxq-show`
This can also be checked with:
```
top -H
taskset -p <pid_of_pmd>
```
To understand where most of the pmd thread time is spent and whether the
caches are being utilized, these commands can be used:
```
# Clear previous stats
ovs-appctl dpif-netdev/pmd-stats-clear
# Check current stats
ovs-appctl dpif-netdev/pmd-stats-show
```
3. DPDK port Rx Queues
`ovs-vsctl set Interface <DPDK interface> options:n_rxq=<integer>`
The command above sets the number of rx queues for DPDK interface.
The rx queues are assigned to pmd threads on the same NUMA node in a
round-robin fashion. For more information, please refer to the
Open_vSwitch TABLE section in
`man ovs-vswitchd.conf.db`
4. Exact Match Cache
Each pmd thread contains one EMC. After initial flow setup in the
datapath, the EMC contains a single table and provides the lowest level
(fastest) switching for DPDK ports. If there is a miss in the EMC then
the next level where switching will occur is the datapath classifier.
Missing in the EMC and looking up in the datapath classifier incurs a
significant performance penalty. If lookup misses occur in the EMC
because it is too small to handle the number of flows, its size can
be increased. The EMC size can be modified by editing the define
EM_FLOW_HASH_SHIFT in lib/dpif-netdev.c.
As mentioned above an EMC is per pmd thread. So an alternative way of
increasing the aggregate amount of possible flow entries in EMC and
avoiding datapath classifier lookups is to have multiple pmd threads
running. This can be done as described in section 2.
5. Compiler options
The default compiler optimization level is '-O2'. Changing this to
more aggressive compiler optimizations such as '-O3' or
'-Ofast -march=native' with gcc can produce performance gains.
6. Simultaneous Multithreading (SMT)
With SMT enabled, one physical core appears as two logical cores
which can improve performance.
SMT can be utilized to add additional pmd threads without consuming
additional physical cores. Additional pmd threads may be added in the
same manner as described in section 2. If trying to minimize the use
of physical cores for pmd threads, care must be taken to set the
correct bits in the pmd-cpu-mask to ensure that the pmd threads are
pinned to SMT siblings.
For example, when using 2x 10 core processors in a dual socket system
with HT enabled, /proc/cpuinfo will report 40 logical cores. To use
two logical cores which share the same physical core for pmd threads,
the following command can be used to identify a pair of logical cores.
`cat /sys/devices/system/cpu/cpuN/topology/thread_siblings_list`
where N is the logical core number. In this example, it would show that
cores 1 and 21 share the same physical core. The pmd-cpu-mask to enable
two pmd threads running on these two logical cores (one physical core)
is.
`ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=100002`
Note that SMT is enabled by the Hyper-Threading section in the
BIOS, and as such will apply to the whole system. So the impact of
enabling/disabling it for the whole system should be considered
e.g. If workloads on the system can scale across multiple cores,
SMT may very beneficial. However, if they do not and perform best
on a single physical core, SMT may not be beneficial.
7. The isolcpus kernel boot parameter
isolcpus can be used on the kernel bootline to isolate cores from the
kernel scheduler and hence dedicate them to OVS or other packet
forwarding related workloads. For example a Linux kernel boot-line
could be:
'GRUB_CMDLINE_LINUX_DEFAULT="quiet hugepagesz=1G hugepages=4 default_hugepagesz=1G 'intel_iommu=off' isolcpus=1-19"'
8. NUMA/Cluster On Die
Ideally inter NUMA datapaths should be avoided where possible as packets
will go across QPI and there may be a slight performance penalty when
compared with intra NUMA datapaths. On Intel Xeon Processor E5 v3,
Cluster On Die is introduced on models that have 10 cores or more.
This makes it possible to logically split a socket into two NUMA regions
and again it is preferred where possible to keep critical datapaths
within the one cluster.
It is good practice to ensure that threads that are in the datapath are
pinned to cores in the same NUMA area. e.g. pmd threads and QEMU vCPUs
responsible for forwarding.
9. Rx Mergeable buffers
Rx Mergeable buffers is a virtio feature that allows chaining of multiple
virtio descriptors to handle large packet sizes. As such, large packets
are handled by reserving and chaining multiple free descriptors
together. Mergeable buffer support is negotiated between the virtio
driver and virtio device and is supported by the DPDK vhost library.
This behavior is typically supported and enabled by default, however
in the case where the user knows that rx mergeable buffers are not needed
i.e. jumbo frames are not needed, it can be forced off by adding
mrg_rxbuf=off to the QEMU command line options. By not reserving multiple
chains of descriptors it will make more individual virtio descriptors
available for rx to the guest using dpdkvhost ports and this can improve
performance.
10. Packet processing in the guest
It is good practice whether simply forwarding packets from one
interface to another or more complex packet processing in the guest,
to ensure that the thread performing this work has as much CPU
occupancy as possible. For example when the DPDK sample application
`testpmd` is used to forward packets in the guest, multiple QEMU vCPU
threads can be created. Taskset can then be used to affinitize the
vCPU thread responsible for forwarding to a dedicated core not used
for other general processing on the host system.
11. DPDK virtio pmd in the guest
dpdkvhostcuse or dpdkvhostuser ports can be used to accelerate the path
to the guest using the DPDK vhost library. This library is compatible with
virtio-net drivers in the guest but significantly better performance can
be observed when using the DPDK virtio pmd driver in the guest. The DPDK
`testpmd` application can be used in the guest as an example application
that forwards packet from one DPDK vhost port to another. An example of
running `testpmd` in the guest can be seen here.
`./testpmd -c 0x3 -n 4 --socket-mem 512 -- --burst=64 -i --txqflags=0xf00 --disable-hw-vlan --forward-mode=io --auto-start`
See below information on dpdkvhostcuse and dpdkvhostuser ports.
See [DPDK Docs] for more information on `testpmd`.
DPDK Rings :
------------
Following the steps above to create a bridge, you can now add dpdk rings
as a port to the vswitch. OVS will expect the DPDK ring device name to
start with dpdkr and end with a portid.
`ovs-vsctl add-port br0 dpdkr0 -- set Interface dpdkr0 type=dpdkr`
DPDK rings client test application
Included in the test directory is a sample DPDK application for testing
the rings. This is from the base dpdk directory and modified to work
with the ring naming used within ovs.
location tests/ovs_client
To run the client :
```
cd /usr/src/ovs/tests/
ovsclient -c 1 -n 4 --proc-type=secondary -- -n "port id you gave dpdkr"
```
In the case of the dpdkr example above the "port id you gave dpdkr" is 0.
It is essential to have --proc-type=secondary
The application simply receives an mbuf on the receive queue of the
ethernet ring and then places that same mbuf on the transmit ring of
the ethernet ring. It is a trivial loopback application.
DPDK rings in VM (IVSHMEM shared memory communications)
-------------------------------------------------------
In addition to executing the client in the host, you can execute it within
a guest VM. To do so you will need a patched qemu. You can download the
patch and getting started guide at :
https://01.org/packet-processing/downloads
A general rule of thumb for better performance is that the client
application should not be assigned the same dpdk core mask "-c" as
the vswitchd.
DPDK vhost:
-----------
DPDK 2.2 supports two types of vhost:
1. vhost-user
2. vhost-cuse
Whatever type of vhost is enabled in the DPDK build specified, is the type
that will be enabled in OVS. By default, vhost-user is enabled in DPDK.
Therefore, unless vhost-cuse has been enabled in DPDK, vhost-user ports
will be enabled in OVS.
Please note that support for vhost-cuse is intended to be deprecated in OVS
in a future release.
DPDK vhost-user:
----------------
The following sections describe the use of vhost-user 'dpdkvhostuser' ports
with OVS.
DPDK vhost-user Prerequisites:
-------------------------
1. DPDK 2.2 with vhost support enabled as documented in the "Building and
Installing section"
2. QEMU version v2.1.0+
QEMU v2.1.0 will suffice, but it is recommended to use v2.2.0 if providing
your VM with memory greater than 1GB due to potential issues with memory
mapping larger areas.
Adding DPDK vhost-user ports to the Switch:
--------------------------------------
Following the steps above to create a bridge, you can now add DPDK vhost-user
as a port to the vswitch. Unlike DPDK ring ports, DPDK vhost-user ports can
have arbitrary names, except that forward and backward slashes are prohibited
in the names.
- For vhost-user, the name of the port type is `dpdkvhostuser`
```
ovs-vsctl add-port br0 vhost-user-1 -- set Interface vhost-user-1
type=dpdkvhostuser
```
This action creates a socket located at
`/usr/local/var/run/openvswitch/vhost-user-1`, which you must provide
to your VM on the QEMU command line. More instructions on this can be
found in the next section "DPDK vhost-user VM configuration"
Note: If you wish for the vhost-user sockets to be created in a
directory other than `/usr/local/var/run/openvswitch`, you may specify
another location on the ovs-vswitchd command line like so:
`./vswitchd/ovs-vswitchd --dpdk -vhost_sock_dir /my-dir -c 0x1 ...`
DPDK vhost-user VM configuration:
---------------------------------
Follow the steps below to attach vhost-user port(s) to a VM.
1. Configure sockets.
Pass the following parameters to QEMU to attach a vhost-user device:
```
-chardev socket,id=char1,path=/usr/local/var/run/openvswitch/vhost-user-1
-netdev type=vhost-user,id=mynet1,chardev=char1,vhostforce
-device virtio-net-pci,mac=00:00:00:00:00:01,netdev=mynet1
```
...where vhost-user-1 is the name of the vhost-user port added
to the switch.
Repeat the above parameters for multiple devices, changing the
chardev path and id as necessary. Note that a separate and different
chardev path needs to be specified for each vhost-user device. For
example you have a second vhost-user port named 'vhost-user-2', you
append your QEMU command line with an additional set of parameters:
```
-chardev socket,id=char2,path=/usr/local/var/run/openvswitch/vhost-user-2
-netdev type=vhost-user,id=mynet2,chardev=char2,vhostforce
-device virtio-net-pci,mac=00:00:00:00:00:02,netdev=mynet2
```
2. Configure huge pages.
QEMU must allocate the VM's memory on hugetlbfs. vhost-user ports access
a virtio-net device's virtual rings and packet buffers mapping the VM's
physical memory on hugetlbfs. To enable vhost-user ports to map the VM's
memory into their process address space, pass the following paramters
to QEMU:
```
-object memory-backend-file,id=mem,size=4096M,mem-path=/dev/hugepages,
share=on
-numa node,memdev=mem -mem-prealloc
```
3. Optional: Enable multiqueue support
The vhost-user interface must be configured in Open vSwitch with the
desired amount of queues with:
```
ovs-vsctl set Interface vhost-user-2 options:n_rxq=<requested queues>
```
QEMU needs to be configured as well.
The $q below should match the queues requested in OVS (if $q is more,
packets will not be received).
The $v is the number of vectors, which is '$q x 2 + 2'.
```
-chardev socket,id=char2,path=/usr/local/var/run/openvswitch/vhost-user-2
-netdev type=vhost-user,id=mynet2,chardev=char2,vhostforce,queues=$q
-device virtio-net-pci,mac=00:00:00:00:00:02,netdev=mynet2,mq=on,vectors=$v
```
If one wishes to use multiple queues for an interface in the guest, the
driver in the guest operating system must be configured to do so. It is
recommended that the number of queues configured be equal to '$q'.
For example, this can be done for the Linux kernel virtio-net driver with:
```
ethtool -L <DEV> combined <$q>
```
A note on the command above:
`-L`: Changes the numbers of channels of the specified network device
`combined`: Changes the number of multi-purpose channels.
DPDK vhost-cuse:
----------------
The following sections describe the use of vhost-cuse 'dpdkvhostcuse' ports
with OVS.
DPDK vhost-cuse Prerequisites:
-------------------------
1. DPDK 2.2 with vhost support enabled as documented in the "Building and
Installing section"
As an additional step, you must enable vhost-cuse in DPDK by setting the
following additional flag in `config/common_linuxapp`:
`CONFIG_RTE_LIBRTE_VHOST_USER=n`
Following this, rebuild DPDK as per the instructions in the "Building and
Installing" section. Finally, rebuild OVS as per step 3 in the "Building
and Installing" section - OVS will detect that DPDK has vhost-cuse libraries
compiled and in turn will enable support for it in the switch and disable
vhost-user support.
2. Insert the Cuse module:
`modprobe cuse`
3. Build and insert the `eventfd_link` module:
```
cd $DPDK_DIR/lib/librte_vhost/eventfd_link/
make
insmod $DPDK_DIR/lib/librte_vhost/eventfd_link.ko
```
4. QEMU version v2.1.0+
vhost-cuse will work with QEMU v2.1.0 and above, however it is recommended to
use v2.2.0 if providing your VM with memory greater than 1GB due to potential
issues with memory mapping larger areas.
Note: QEMU v1.6.2 will also work, with slightly different command line parameters,
which are specified later in this document.
Adding DPDK vhost-cuse ports to the Switch:
--------------------------------------
Following the steps above to create a bridge, you can now add DPDK vhost-cuse
as a port to the vswitch. Unlike DPDK ring ports, DPDK vhost-cuse ports can have
arbitrary names.
- For vhost-cuse, the name of the port type is `dpdkvhostcuse`
```
ovs-vsctl add-port br0 vhost-cuse-1 -- set Interface vhost-cuse-1
type=dpdkvhostcuse
```
When attaching vhost-cuse ports to QEMU, the name provided during the
add-port operation must match the ifname parameter on the QEMU command
line. More instructions on this can be found in the next section.
DPDK vhost-cuse VM configuration:
---------------------------------
vhost-cuse ports use a Linux* character device to communicate with QEMU.
By default it is set to `/dev/vhost-net`. It is possible to reuse this
standard device for DPDK vhost, which makes setup a little simpler but it
is better practice to specify an alternative character device in order to
avoid any conflicts if kernel vhost is to be used in parallel.
1. This step is only needed if using an alternative character device.
The new character device filename must be specified on the vswitchd
commandline:
`./vswitchd/ovs-vswitchd --dpdk --cuse_dev_name my-vhost-net -c 0x1 ...`
Note that the `--cuse_dev_name` argument and associated string must be the first
arguments after `--dpdk` and come before the EAL arguments. In the example
above, the character device to be used will be `/dev/my-vhost-net`.
2. This step is only needed if reusing the standard character device. It will
conflict with the kernel vhost character device so the user must first
remove it.
`rm -rf /dev/vhost-net`
3a. Configure virtio-net adaptors:
The following parameters must be passed to the QEMU binary:
```
-netdev tap,id=<id>,script=no,downscript=no,ifname=<name>,vhost=on
-device virtio-net-pci,netdev=net1,mac=<mac>
```
Repeat the above parameters for multiple devices.
The DPDK vhost library will negiotiate its own features, so they
need not be passed in as command line params. Note that as offloads are
disabled this is the equivalent of setting:
`csum=off,gso=off,guest_tso4=off,guest_tso6=off,guest_ecn=off`
3b. If using an alternative character device. It must be also explicitly
passed to QEMU using the `vhostfd` argument:
```
-netdev tap,id=<id>,script=no,downscript=no,ifname=<name>,vhost=on,
vhostfd=<open_fd>
-device virtio-net-pci,netdev=net1,mac=<mac>
```
The open file descriptor must be passed to QEMU running as a child
process. This could be done with a simple python script.
```
#!/usr/bin/python
fd = os.open("/dev/usvhost", os.O_RDWR)
subprocess.call("qemu-system-x86_64 .... -netdev tap,id=vhostnet0,\
vhost=on,vhostfd=" + fd +"...", shell=True)
Alternatively the `qemu-wrap.py` script can be used to automate the
requirements specified above and can be used in conjunction with libvirt if
desired. See the "DPDK vhost VM configuration with QEMU wrapper" section
below.
4. Configure huge pages:
QEMU must allocate the VM's memory on hugetlbfs. Vhost ports access a
virtio-net device's virtual rings and packet buffers mapping the VM's
physical memory on hugetlbfs. To enable vhost-ports to map the VM's
memory into their process address space, pass the following parameters
to QEMU:
`-object memory-backend-file,id=mem,size=4096M,mem-path=/dev/hugepages,
share=on -numa node,memdev=mem -mem-prealloc`
Note: For use with an earlier QEMU version such as v1.6.2, use the
following to configure hugepages instead:
`-mem-path /dev/hugepages -mem-prealloc`
DPDK vhost-cuse VM configuration with QEMU wrapper:
---------------------------------------------------
The QEMU wrapper script automatically detects and calls QEMU with the
necessary parameters. It performs the following actions:
* Automatically detects the location of the hugetlbfs and inserts this
into the command line parameters.
* Automatically open file descriptors for each virtio-net device and
inserts this into the command line parameters.
* Calls QEMU passing both the command line parameters passed to the
script itself and those it has auto-detected.
Before use, you **must** edit the configuration parameters section of the
script to point to the correct emulator location and set additional
settings. Of these settings, `emul_path` and `us_vhost_path` **must** be
set. All other settings are optional.
To use directly from the command line simply pass the wrapper some of the
QEMU parameters: it will configure the rest. For example:
```
qemu-wrap.py -cpu host -boot c -hda <disk image> -m 4096 -smp 4
--enable-kvm -nographic -vnc none -net none -netdev tap,id=net1,
script=no,downscript=no,ifname=if1,vhost=on -device virtio-net-pci,
netdev=net1,mac=00:00:00:00:00:01
```
DPDK vhost-cuse VM configuration with libvirt:
----------------------------------------------
If you are using libvirt, you must enable libvirt to access the character
device by adding it to controllers cgroup for libvirtd using the following
steps.
1. In `/etc/libvirt/qemu.conf` add/edit the following lines:
```
1) clear_emulator_capabilities = 0
2) user = "root"
3) group = "root"
4) cgroup_device_acl = [
"/dev/null", "/dev/full", "/dev/zero",
"/dev/random", "/dev/urandom",
"/dev/ptmx", "/dev/kvm", "/dev/kqemu",
"/dev/rtc", "/dev/hpet", "/dev/net/tun",
"/dev/<my-vhost-device>",
"/dev/hugepages"]
```
<my-vhost-device> refers to "vhost-net" if using the `/dev/vhost-net`
device. If you have specificed a different name on the ovs-vswitchd
commandline using the "--cuse_dev_name" parameter, please specify that
filename instead.
2. Disable SELinux or set to permissive mode
3. Restart the libvirtd process
For example, on Fedora:
`systemctl restart libvirtd.service`
After successfully editing the configuration, you may launch your
vhost-enabled VM. The XML describing the VM can be configured like so
within the <qemu:commandline> section:
1. Set up shared hugepages:
```
<qemu:arg value='-object'/>
<qemu:arg value='memory-backend-file,id=mem,size=4096M,mem-path=/dev/hugepages,share=on'/>
<qemu:arg value='-numa'/>
<qemu:arg value='node,memdev=mem'/>
<qemu:arg value='-mem-prealloc'/>
```
2. Set up your tap devices:
```
<qemu:arg value='-netdev'/>
<qemu:arg value='type=tap,id=net1,script=no,downscript=no,ifname=vhost0,vhost=on'/>
<qemu:arg value='-device'/>
<qemu:arg value='virtio-net-pci,netdev=net1,mac=00:00:00:00:00:01'/>
```
Repeat for as many devices as are desired, modifying the id, ifname
and mac as necessary.
Again, if you are using an alternative character device (other than
`/dev/vhost-net`), please specify the file descriptor like so:
`<qemu:arg value='type=tap,id=net3,script=no,downscript=no,ifname=vhost0,vhost=on,vhostfd=<open_fd>'/>`
Where <open_fd> refers to the open file descriptor of the character device.
Instructions of how to retrieve the file descriptor can be found in the
"DPDK vhost VM configuration" section.
Alternatively, the process is automated with the qemu-wrap.py script,
detailed in the next section.
Now you may launch your VM using virt-manager, or like so:
`virsh create my_vhost_vm.xml`
DPDK vhost-cuse VM configuration with libvirt and QEMU wrapper:
----------------------------------------------------------
To use the qemu-wrapper script in conjuntion with libvirt, follow the
steps in the previous section before proceeding with the following steps:
1. Place `qemu-wrap.py` in libvirtd's binary search PATH ($PATH)
Ideally in the same directory that the QEMU binary is located.
2. Ensure that the script has the same owner/group and file permissions
as the QEMU binary.
3. Update the VM xml file using "virsh edit VM.xml"
1. Set the VM to use the launch script.
Set the emulator path contained in the `<emulator><emulator/>` tags.
For example, replace:
`<emulator>/usr/bin/qemu-kvm<emulator/>`
with:
`<emulator>/usr/bin/qemu-wrap.py<emulator/>`
4. Edit the Configuration Parameters section of the script to point to
the correct emulator location and set any additional options. If you are
using a alternative character device name, please set "us_vhost_path" to the
location of that device. The script will automatically detect and insert
the correct "vhostfd" value in the QEMU command line arguments.
5. Use virt-manager to launch the VM
Running ovs-vswitchd with DPDK backend inside a VM
--------------------------------------------------
Please note that additional configuration is required if you want to run
ovs-vswitchd with DPDK backend inside a QEMU virtual machine. Ovs-vswitchd
creates separate DPDK TX queues for each CPU core available. This operation
fails inside QEMU virtual machine because, by default, VirtIO NIC provided
to the guest is configured to support only single TX queue and single RX
queue. To change this behavior, you need to turn on 'mq' (multiqueue)
property of all virtio-net-pci devices emulated by QEMU and used by DPDK.
You may do it manually (by changing QEMU command line) or, if you use Libvirt,
by adding the following string:
`<driver name='vhost' queues='N'/>`
to <interface> sections of all network devices used by DPDK. Parameter 'N'
determines how many queues can be used by the guest.
Restrictions:
-------------
- Work with 1500 MTU, needs few changes in DPDK lib to fix this issue.
- Currently DPDK port does not make use any offload functionality.
- DPDK-vHost support works with 1G huge pages.
ivshmem:
- If you run Open vSwitch with smaller page sizes (e.g. 2MB), you may be
unable to share any rings or mempools with a virtual machine.
This is because the current implementation of ivshmem works by sharing
a single 1GB huge page from the host operating system to any guest
operating system through the Qemu ivshmem device. When using smaller
page sizes, multiple pages may be required to hold the ring descriptors
and buffer pools. The Qemu ivshmem device does not allow you to share
multiple file descriptors to the guest operating system. However, if you
want to share dpdkr rings with other processes on the host, you can do
this with smaller page sizes.
Platform and Network Interface:
- By default with DPDK 2.2, a maximum of 64 TX queues can be used with an
Intel XL710 Network Interface on a platform with more than 64 logical
cores. If a user attempts to add an XL710 interface as a DPDK port type to
a system as described above, an error will be reported that initialization
failed for the 65th queue. OVS will then roll back to the previous
successful queue initialization and use that value as the total number of
TX queues available with queue locking. If a user wishes to use more than
64 queues and avoid locking, then the
`CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF` config parameter in DPDK must be
increased to the desired number of queues. Both DPDK and OVS must be
recompiled for this change to take effect.
Bug Reporting:
--------------
Please report problems to bugs@openvswitch.org.
[INSTALL.userspace.md]:INSTALL.userspace.md
[INSTALL.md]:INSTALL.md
[DPDK Linux GSG]: http://www.dpdk.org/doc/guides/linux_gsg/build_dpdk.html#binding-and-unbinding-network-ports-to-from-the-igb-uioor-vfio-modules
[DPDK Docs]: http://dpdk.org/doc
|