summaryrefslogtreecommitdiff
path: root/ovn/ovn-architecture.7.xml
blob: ead4feb7199d8c8631d52c3daa8b9fde71bc781e (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
<?xml version="1.0" encoding="utf-8"?>
<manpage program="ovn-architecture" section="7" title="OVN Architecture">
  <h1>Name</h1>
  <p>ovn-architecture -- Open Virtual Network architecture</p>

  <h1>Description</h1>

  <p>
    OVN, the Open Virtual Network, is a system to support virtual network
    abstraction.  OVN complements the existing capabilities of OVS to add
    native support for virtual network abstractions, such as virtual L2 and L3
    overlays and security groups.  Services such as DHCP are also desirable
    features.  Just like OVS, OVN's design goal is to have a production-quality
    implementation that can operate at significant scale.
  </p>

  <p>
    An OVN deployment consists of several components:
  </p>

  <ul>
    <li>
      <p>
        A <dfn>Cloud Management System</dfn> (<dfn>CMS</dfn>), which is
        OVN's ultimate client (via its users and administrators).  OVN
        integration requires installing a CMS-specific plugin and
        related software (see below).  OVN initially targets OpenStack
        as CMS.
      </p>

      <p>
        We generally speak of ``the'' CMS, but one can imagine scenarios in
        which multiple CMSes manage different parts of an OVN deployment.
      </p>
    </li>

    <li>
      An OVN Database physical or virtual node (or, eventually, cluster)
      installed in a central location.
    </li>

    <li>
      One or more (usually many) <dfn>hypervisors</dfn>.  Hypervisors must run
      Open vSwitch and implement the interface described in
      <code>IntegrationGuide.md</code> in the OVS source tree.  Any hypervisor
      platform supported by Open vSwitch is acceptable.
    </li>

    <li>
      <p>
        Zero or more <dfn>gateways</dfn>.  A gateway extends a tunnel-based
        logical network into a physical network by bidirectionally forwarding
        packets between tunnels and a physical Ethernet port.  This allows
        non-virtualized machines to participate in logical networks.  A gateway
        may be a physical host, a virtual machine, or an ASIC-based hardware
        switch that supports the <code>vtep</code>(5) schema.  (Support for the
        latter will come later in OVN implementation.)
      </p>

      <p>
        Hypervisors and gateways are together called <dfn>transport node</dfn>
        or <dfn>chassis</dfn>.
      </p>
    </li>
  </ul>

  <p>
    The diagram below shows how the major components of OVN and related
    software interact.  Starting at the top of the diagram, we have:
  </p>

  <ul>
    <li>
      The Cloud Management System, as defined above.
    </li>

    <li>
      <p>
        The <dfn>OVN/CMS Plugin</dfn> is the component of the CMS that
        interfaces to OVN.  In OpenStack, this is a Neutron plugin.
        The plugin's main purpose is to translate the CMS's notion of logical
        network configuration, stored in the CMS's configuration database in a
        CMS-specific format, into an intermediate representation understood by
        OVN.
      </p>

      <p>
        This component is necessarily CMS-specific, so a new plugin needs to be
        developed for each CMS that is integrated with OVN.  All of the
        components below this one in the diagram are CMS-independent.
      </p>
    </li>

    <li>
      <p>
        The <dfn>OVN Northbound Database</dfn> receives the intermediate
        representation of logical network configuration passed down by the
        OVN/CMS Plugin.  The database schema is meant to be ``impedance
        matched'' with the concepts used in a CMS, so that it directly supports
        notions of logical switches, routers, ACLs, and so on.  See
        <code>ovn-nb</code>(5) for details.
      </p>

      <p>
        The OVN Northbound Database has only two clients: the OVN/CMS Plugin
        above it and <code>ovn-northd</code> below it.
      </p>
    </li>

    <li>
      <code>ovn-northd</code>(8) connects to the OVN Northbound Database
      above it and the OVN Southbound Database below it.  It translates the
      logical network configuration in terms of conventional network
      concepts, taken from the OVN Northbound Database, into logical
      datapath flows in the OVN Southbound Database below it.
    </li>

    <li>
      <p>
    The <dfn>OVN Southbound Database</dfn> is the center of the system.
    Its clients are <code>ovn-northd</code>(8) above it and
    <code>ovn-controller</code>(8) on every transport node below it.
      </p>

      <p>
        The OVN Southbound Database contains three kinds of data: <dfn>Physical
        Network</dfn> (PN) tables that specify how to reach hypervisor and
        other nodes, <dfn>Logical Network</dfn> (LN) tables that describe the
        logical network in terms of ``logical datapath flows,'' and
        <dfn>Binding</dfn> tables that link logical network components'
        locations to the physical network.  The hypervisors populate the PN and
        Port_Binding tables, whereas <code>ovn-northd</code>(8) populates the
        LN tables.
      </p>

      <p>
    OVN Southbound Database performance must scale with the number of
    transport nodes.  This will likely require some work on
    <code>ovsdb-server</code>(1) as we encounter bottlenecks.
    Clustering for availability may be needed.
      </p>
    </li>
  </ul>

  <p>
    The remaining components are replicated onto each hypervisor:
  </p>

  <ul>
    <li>
      <code>ovn-controller</code>(8) is OVN's agent on each hypervisor and
      software gateway.  Northbound, it connects to the OVN Southbound
      Database to learn about OVN configuration and status and to
      populate the PN table and the <code>Chassis</code> column in
      <code>Binding</code> table with the hypervisor's status.
      Southbound, it connects to <code>ovs-vswitchd</code>(8) as an
      OpenFlow controller, for control over network traffic, and to the
      local <code>ovsdb-server</code>(1) to allow it to monitor and
      control Open vSwitch configuration.
    </li>

    <li>
      <code>ovs-vswitchd</code>(8) and <code>ovsdb-server</code>(1) are
      conventional components of Open vSwitch.
    </li>
  </ul>

  <pre fixed="yes">
                                  CMS
                                   |
                                   |
                       +-----------|-----------+
                       |           |           |
                       |     OVN/CMS Plugin    |
                       |           |           |
                       |           |           |
                       |   OVN Northbound DB   |
                       |           |           |
                       |           |           |
                       |       ovn-northd      |
                       |           |           |
                       +-----------|-----------+
                                   |
                                   |
                         +-------------------+
                         | OVN Southbound DB |
                         +-------------------+
                                   |
                                   |
                +------------------+------------------+
                |                  |                  |
  HV 1          |                  |    HV n          |
+---------------|---------------+  .  +---------------|---------------+
|               |               |  .  |               |               |
|        ovn-controller         |  .  |        ovn-controller         |
|         |          |          |  .  |         |          |          |
|         |          |          |     |         |          |          |
|  ovs-vswitchd   ovsdb-server  |     |  ovs-vswitchd   ovsdb-server  |
|                               |     |                               |
+-------------------------------+     +-------------------------------+
  </pre>

  <h2>Chassis Setup</h2>

  <p>
    Each chassis in an OVN deployment must be configured with an Open vSwitch
    bridge dedicated for OVN's use, called the <dfn>integration bridge</dfn>.
    System startup scripts may create this bridge prior to starting
    <code>ovn-controller</code> if desired.  If this bridge does not exist when
    ovn-controller starts, it will be created automatically with the default
    configuration suggested below.  The ports on the integration bridge include:
  </p>

  <ul>
    <li>
      On any chassis, tunnel ports that OVN uses to maintain logical network
      connectivity.  <code>ovn-controller</code> adds, updates, and removes
      these tunnel ports.
    </li>

    <li>
      On a hypervisor, any VIFs that are to be attached to logical networks.
      The hypervisor itself, or the integration between Open vSwitch and the
      hypervisor (described in <code>IntegrationGuide.md</code>) takes care of
      this.  (This is not part of OVN or new to OVN; this is pre-existing
      integration work that has already been done on hypervisors that support
      OVS.)
    </li>

    <li>
      On a gateway, the physical port used for logical network connectivity.
      System startup scripts add this port to the bridge prior to starting
      <code>ovn-controller</code>.  This can be a patch port to another bridge,
      instead of a physical port, in more sophisticated setups.
    </li>
  </ul>

  <p>
    Other ports should not be attached to the integration bridge.  In
    particular, physical ports attached to the underlay network (as opposed to
    gateway ports, which are physical ports attached to logical networks) must
    not be attached to the integration bridge.  Underlay physical ports should
    instead be attached to a separate Open vSwitch bridge (they need not be
    attached to any bridge at all, in fact).
  </p>

  <p>
    The integration bridge should be configured as described below.
    The effect of each of these settings is documented in
    <code>ovs-vswitchd.conf.db</code>(5):
  </p>

  <!-- Keep the following in sync with create_br_int() in
       ovn/controller/ovn-controller.c. -->
  <dl>
    <dt><code>fail-mode=secure</code></dt>
    <dd>
      Avoids switching packets between isolated logical networks before
      <code>ovn-controller</code> starts up.  See <code>Controller Failure
      Settings</code> in <code>ovs-vsctl</code>(8) for more information.
    </dd>

    <dt><code>other-config:disable-in-band=true</code></dt>
    <dd>
      Suppresses in-band control flows for the integration bridge.  It would be
      unusual for such flows to show up anyway, because OVN uses a local
      controller (over a Unix domain socket) instead of a remote controller.
      It's possible, however, for some other bridge in the same system to have
      an in-band remote controller, and in that case this suppresses the flows
      that in-band control would ordinarily set up.  See <code>In-Band
      Control</code> in <code>DESIGN.md</code> for more information.
    </dd>
  </dl>

  <p>
    The customary name for the integration bridge is <code>br-int</code>, but
    another name may be used.
  </p>

  <h2>Logical Networks</h2>

  <p>
    A <dfn>logical network</dfn> implements the same concepts as physical
    networks, but they are insulated from the physical network with tunnels or
    other encapsulations.  This allows logical networks to have separate IP and
    other address spaces that overlap, without conflicting, with those used for
    physical networks.  Logical network topologies can be arranged without
    regard for the topologies of the physical networks on which they run.
  </p>

  <p>
    Logical network concepts in OVN include:
  </p>

  <ul>
    <li>
      <dfn>Logical switches</dfn>, the logical version of Ethernet switches.
    </li>

    <li>
      <dfn>Logical routers</dfn>, the logical version of IP routers.  Logical
      switches and routers can be connected into sophisticated topologies.
    </li>

    <li>
      <dfn>Logical datapaths</dfn> are the logical version of an OpenFlow
      switch.  Logical switches and routers are both implemented as logical
      datapaths.
    </li>
  </ul>

  <h2>Life Cycle of a VIF</h2>

  <p>
    Tables and their schemas presented in isolation are difficult to
    understand.  Here's an example.
  </p>

  <p>
    A VIF on a hypervisor is a virtual network interface attached either
    to a VM or a container running directly on that hypervisor (This is
    different from the interface of a container running inside a VM).
  </p>

  <p>
    The steps in this example refer often to details of the OVN and OVN
    Northbound database schemas.  Please see <code>ovn-sb</code>(5) and
    <code>ovn-nb</code>(5), respectively, for the full story on these
    databases.
  </p>

  <ol>
    <li>
      A VIF's life cycle begins when a CMS administrator creates a new VIF
      using the CMS user interface or API and adds it to a switch (one
      implemented by OVN as a logical switch).  The CMS updates its own
      configuration.  This includes associating unique, persistent identifier
      <var>vif-id</var> and Ethernet address <var>mac</var> with the VIF.
    </li>

    <li>
      The CMS plugin updates the OVN Northbound database to include the new
      VIF, by adding a row to the <code>Logical_Switch_Port</code>
      table.  In the new row, <code>name</code> is <var>vif-id</var>,
      <code>mac</code> is <var>mac</var>, <code>switch</code> points to
      the OVN logical switch's Logical_Switch record, and other columns
      are initialized appropriately.
    </li>

    <li>
      <code>ovn-northd</code> receives the OVN Northbound database update.  In
      turn, it makes the corresponding updates to the OVN Southbound database,
      by adding rows to the OVN Southbound database <code>Logical_Flow</code>
      table to reflect the new port, e.g. add a flow to recognize that packets
      destined to the new port's MAC address should be delivered to it, and
      update the flow that delivers broadcast and multicast packets to include
      the new port.  It also creates a record in the <code>Binding</code> table
      and populates all its columns except the column that identifies the
      <code>chassis</code>.
    </li>

    <li>
      On every hypervisor, <code>ovn-controller</code> receives the
      <code>Logical_Flow</code> table updates that <code>ovn-northd</code> made
      in the previous step.  As long as the VM that owns the VIF is powered
      off, <code>ovn-controller</code> cannot do much; it cannot, for example,
      arrange to send packets to or receive packets from the VIF, because the
      VIF does not actually exist anywhere.
    </li>

    <li>
      Eventually, a user powers on the VM that owns the VIF.  On the hypervisor
      where the VM is powered on, the integration between the hypervisor and
      Open vSwitch (described in <code>IntegrationGuide.md</code>) adds the VIF
      to the OVN integration bridge and stores <var>vif-id</var> in
      <code>external-ids</code>:<code>iface-id</code> to indicate that the
      interface is an instantiation of the new VIF.  (None of this code is new
      in OVN; this is pre-existing integration work that has already been done
      on hypervisors that support OVS.)
    </li>

    <li>
      On the hypervisor where the VM is powered on, <code>ovn-controller</code>
      notices <code>external-ids</code>:<code>iface-id</code> in the new
      Interface. In response, in the OVN Southbound DB, it updates the
      <code>Binding</code> table's <code>chassis</code> column for the
      row that links the logical port from <code>external-ids</code>:<code>
      iface-id</code> to the hypervisor. Afterward, <code>ovn-controller</code>
      updates the local hypervisor's OpenFlow tables so that packets to and from
      the VIF are properly handled.
    </li>

    <li>
      Some CMS systems, including OpenStack, fully start a VM only when its
      networking is ready.  To support this, <code>ovn-northd</code> notices
      the <code>chassis</code> column updated for the row in
      <code>Binding</code> table and pushes this upward by updating the
      <ref column="up" table="Logical_Switch_Port" db="OVN_NB"/> column
      in the OVN Northbound database's <ref table="Logical_Switch_Port"
      db="OVN_NB"/> table to indicate that the VIF is now up.  The CMS,
      if it uses this feature, can then react by allowing the VM's
      execution to proceed.
    </li>

    <li>
      On every hypervisor but the one where the VIF resides,
      <code>ovn-controller</code> notices the completely populated row in the
      <code>Binding</code> table.  This provides <code>ovn-controller</code>
      the physical location of the logical port, so each instance updates the
      OpenFlow tables of its switch (based on logical datapath flows in the OVN
      DB <code>Logical_Flow</code> table) so that packets to and from the VIF
      can be properly handled via tunnels.
    </li>

    <li>
      Eventually, a user powers off the VM that owns the VIF.  On the
      hypervisor where the VM was powered off, the VIF is deleted from the OVN
      integration bridge.
    </li>

    <li>
      On the hypervisor where the VM was powered off,
      <code>ovn-controller</code> notices that the VIF was deleted.  In
      response, it removes the <code>Chassis</code> column content in the
      <code>Binding</code> table for the logical port.
    </li>

    <li>
      On every hypervisor, <code>ovn-controller</code> notices the empty
      <code>Chassis</code> column in the <code>Binding</code> table's row
      for the logical port.  This means that <code>ovn-controller</code> no
      longer knows the physical location of the logical port, so each instance
      updates its OpenFlow table to reflect that.
    </li>

    <li>
      Eventually, when the VIF (or its entire VM) is no longer needed by
      anyone, an administrator deletes the VIF using the CMS user interface or
      API.  The CMS updates its own configuration.
    </li>

    <li>
      The CMS plugin removes the VIF from the OVN Northbound database,
      by deleting its row in the <code>Logical_Switch_Port</code> table.
    </li>

    <li>
      <code>ovn-northd</code> receives the OVN Northbound update and in turn
      updates the OVN Southbound database accordingly, by removing or updating
      the rows from the OVN Southbound database <code>Logical_Flow</code> table
      and <code>Binding</code> table that were related to the now-destroyed
      VIF.
    </li>

    <li>
      On every hypervisor, <code>ovn-controller</code> receives the
      <code>Logical_Flow</code> table updates that <code>ovn-northd</code> made
      in the previous step.  <code>ovn-controller</code> updates OpenFlow
      tables to reflect the update, although there may not be much to do, since
      the VIF had already become unreachable when it was removed from the
      <code>Binding</code> table in a previous step.
    </li>
  </ol>

  <h2>Life Cycle of a Container Interface Inside a VM</h2>

  <p>
    OVN provides virtual network abstractions by converting information
    written in OVN_NB database to OpenFlow flows in each hypervisor.  Secure
    virtual networking for multi-tenants can only be provided if OVN controller
    is the only entity that can modify flows in Open vSwitch.  When the
    Open vSwitch integration bridge resides in the hypervisor, it is a
    fair assumption to make that tenant workloads running inside VMs cannot
    make any changes to Open vSwitch flows.
  </p>

  <p>
    If the infrastructure provider trusts the applications inside the
    containers not to break out and modify the Open vSwitch flows, then
    containers can be run in hypervisors.  This is also the case when
    containers are run inside the VMs and Open vSwitch integration bridge
    with flows added by OVN controller resides in the same VM.  For both
    the above cases, the workflow is the same as explained with an example
    in the previous section ("Life Cycle of a VIF").
  </p>

  <p>
    This section talks about the life cycle of a container interface (CIF)
    when containers are created in the VMs and the Open vSwitch integration
    bridge resides inside the hypervisor.  In this case, even if a container
    application breaks out, other tenants are not affected because the
    containers running inside the VMs cannot modify the flows in the
    Open vSwitch integration bridge.
  </p>

  <p>
    When multiple containers are created inside a VM, there are multiple
    CIFs associated with them.  The network traffic associated with these
    CIFs need to reach the Open vSwitch integration bridge running in the
    hypervisor for OVN to support virtual network abstractions.  OVN should
    also be able to distinguish network traffic coming from different CIFs.
    There are two ways to distinguish network traffic of CIFs.
  </p>

  <p>
    One way is to provide one VIF for every CIF (1:1 model).  This means that
    there could be a lot of network devices in the hypervisor.  This would slow
    down OVS because of all the additional CPU cycles needed for the management
    of all the VIFs.  It would also mean that the entity creating the
    containers in a VM should also be able to create the corresponding VIFs in
    the hypervisor.
  </p>

  <p>
    The second way is to provide a single VIF for all the CIFs (1:many model).
    OVN could then distinguish network traffic coming from different CIFs via
    a tag written in every packet.  OVN uses this mechanism and uses VLAN as
    the tagging mechanism.
  </p>

  <ol>
    <li>
      A CIF's life cycle begins when a container is spawned inside a VM by
      the either the same CMS that created the VM or a tenant that owns that VM
      or even a container Orchestration System that is different than the CMS
      that initially created the VM.  Whoever the entity is, it will need to
      know the <var>vif-id</var> that is associated with the network interface
      of the VM through which the container interface's network traffic is
      expected to go through.  The entity that creates the container interface
      will also need to choose an unused VLAN inside that VM.
    </li>

    <li>
      The container spawning entity (either directly or through the CMS that
      manages the underlying infrastructure) updates the OVN Northbound
      database to include the new CIF, by adding a row to the
      <code>Logical_Switch_Port</code> table.  In the new row,
      <code>name</code> is any unique identifier,
      <code>parent_name</code> is the <var>vif-id</var> of the VM
      through which the CIF's network traffic is expected to go through
      and the <code>tag</code> is the VLAN tag that identifies the
      network traffic of that CIF.
    </li>

    <li>
      <code>ovn-northd</code> receives the OVN Northbound database update.  In
      turn, it makes the corresponding updates to the OVN Southbound database,
      by adding rows to the OVN Southbound database's <code>Logical_Flow</code>
      table to reflect the new port and also by creating a new row in the
      <code>Binding</code> table and populating all its columns except the
      column that identifies the <code>chassis</code>.
    </li>

    <li>
      On every hypervisor, <code>ovn-controller</code> subscribes to the
      changes in the <code>Binding</code> table.  When a new row is created
      by <code>ovn-northd</code> that includes a value in
      <code>parent_port</code> column of <code>Binding</code> table, the
      <code>ovn-controller</code> in the hypervisor whose OVN integration bridge
      has that same value in <var>vif-id</var> in
      <code>external-ids</code>:<code>iface-id</code>
      updates the local hypervisor's OpenFlow tables so that packets to and
      from the VIF with the particular VLAN <code>tag</code> are properly
      handled.  Afterward it updates the <code>chassis</code> column of
      the <code>Binding</code> to reflect the physical location.
    </li>

    <li>
      One can only start the application inside the container after the
      underlying network is ready.  To support this, <code>ovn-northd</code>
      notices the updated <code>chassis</code> column in <code>Binding</code>
      table and updates the <ref column="up" table="Logical_Switch_Port"
      db="OVN_NB"/> column in the OVN Northbound database's
      <ref table="Logical_Switch_Port" db="OVN_NB"/> table to indicate that the
      CIF is now up.  The entity responsible to start the container application
      queries this value and starts the application.
    </li>

    <li>
      Eventually the entity that created and started the container, stops it.
      The entity, through the CMS (or directly) deletes its row in the
      <code>Logical_Switch_Port</code> table.
    </li>

    <li>
      <code>ovn-northd</code> receives the OVN Northbound update and in turn
      updates the OVN Southbound database accordingly, by removing or updating
      the rows from the OVN Southbound database <code>Logical_Flow</code> table
      that were related to the now-destroyed CIF.  It also deletes the row in
      the <code>Binding</code> table for that CIF.
    </li>

    <li>
      On every hypervisor, <code>ovn-controller</code> receives the
      <code>Logical_Flow</code> table updates that <code>ovn-northd</code> made
      in the previous step.  <code>ovn-controller</code> updates OpenFlow
      tables to reflect the update.
    </li>
  </ol>

  <h2>Architectural Physical Life Cycle of a Packet</h2>

  <p>
    This section describes how a packet travels from one virtual machine or
    container to another through OVN.  This description focuses on the physical
    treatment of a packet; for a description of the logical life cycle of a
    packet, please refer to the <code>Logical_Flow</code> table in
    <code>ovn-sb</code>(5).
  </p>

  <p>
    This section mentions several data and metadata fields, for clarity
    summarized here:
  </p>

  <dl>
    <dt>tunnel key</dt>
    <dd>
      When OVN encapsulates a packet in Geneve or another tunnel, it attaches
      extra data to it to allow the receiving OVN instance to process it
      correctly.  This takes different forms depending on the particular
      encapsulation, but in each case we refer to it here as the ``tunnel
      key.''  See <code>Tunnel Encapsulations</code>, below, for details.
    </dd>

    <dt>logical datapath field</dt>
    <dd>
      A field that denotes the logical datapath through which a packet is being
      processed.
      <!-- Keep the following in sync with MFF_LOG_DATAPATH in
           ovn/lib/logical-fields.h. -->
      OVN uses the field that OpenFlow 1.1+ simply (and confusingly) calls
      ``metadata'' to store the logical datapath.  (This field is passed across
      tunnels as part of the tunnel key.)
    </dd>

    <dt>logical input port field</dt>
    <dd>
      <p>
        A field that denotes the logical port from which the packet
        entered the logical datapath.
        <!-- Keep the following in sync with MFF_LOG_INPORT in
             ovn/lib/logical-fields.h. -->
        OVN stores this in Nicira extension register number 14.
      </p>

      <p>
        Geneve and STT tunnels pass this field as part of the tunnel key.
        Although VXLAN tunnels do not explicitly carry a logical input port,
        OVN only uses VXLAN to communicate with gateways that from OVN's
        perspective consist of only a single logical port, so that OVN can set
        the logical input port field to this one on ingress to the OVN logical
        pipeline.
      </p>
    </dd>

    <dt>logical output port field</dt>
    <dd>
      <p>
        A field that denotes the logical port from which the packet will
        leave the logical datapath.  This is initialized to 0 at the
        beginning of the logical ingress pipeline.
        <!-- Keep the following in sync with MFF_LOG_OUTPORT in
             ovn/lib/logical-fields.h. -->
        OVN stores this in Nicira extension register number 15.
      </p>

      <p>
        Geneve and STT tunnels pass this field as part of the tunnel key.
        VXLAN tunnels do not transmit the logical output port field.
      </p>
    </dd>

    <dt>conntrack zone field for logical ports</dt>
    <dd>
      A field that denotes the connection tracking zone for logical ports.
      The value only has local significance and is not meaningful between
      chassis.  This is initialized to 0 at the beginning of the logical
        <!-- Keep the following in sync with MFF_LOG_CT_ZONE in
             ovn/lib/logical-fields.h. -->
      ingress pipeline.  OVN stores this in Nicira extension register
      number 13.
    </dd>

    <dt>conntrack zone fields for Gateway router</dt>
    <dd>
      Fields that denote the connection tracking zones for Gateway routers.
      These values only have local significance (only on chassis that have
      Gateway routers instantiated) and is not meaningful between
      chassis.  OVN stores the zone information for DNATting in Nicira
        <!-- Keep the following in sync with MFF_LOG_DNAT_ZONE and
        MFF_LOG_SNAT_ZONE in ovn/lib/logical-fields.h. -->
      extension register number 11 and zone information for SNATing in Nicira
      extension register number 12.
    </dd>

    <dt>VLAN ID</dt>
    <dd>
      The VLAN ID is used as an interface between OVN and containers nested
      inside a VM (see <code>Life Cycle of a container interface inside a
      VM</code>, above, for more information).
    </dd>
  </dl>

  <p>
    Initially, a VM or container on the ingress hypervisor sends a packet on a
    port attached to the OVN integration bridge.  Then:
  </p>

  <ol>
    <li>
      <p>
        OpenFlow table 0 performs physical-to-logical translation.  It matches
        the packet's ingress port.  Its actions annotate the packet with
        logical metadata, by setting the logical datapath field to identify the
        logical datapath that the packet is traversing and the logical input
        port field to identify the ingress port.  Then it resubmits to table 16
        to enter the logical ingress pipeline.
      </p>

      <p>
        Packets that originate from a container nested within a VM are treated
        in a slightly different way.  The originating container can be
        distinguished based on the VIF-specific VLAN ID, so the
        physical-to-logical translation flows additionally match on VLAN ID and
        the actions strip the VLAN header.  Following this step, OVN treats
        packets from containers just like any other packets.
      </p>

      <p>
        Table 0 also processes packets that arrive from other chassis.  It
        distinguishes them from other packets by ingress port, which is a
        tunnel.  As with packets just entering the OVN pipeline, the actions
        annotate these packets with logical datapath and logical ingress port
        metadata.  In addition, the actions set the logical output port field,
        which is available because in OVN tunneling occurs after the logical
        output port is known.  These three pieces of information are obtained
        from the tunnel encapsulation metadata (see <code>Tunnel
        Encapsulations</code> for encoding details).  Then the actions resubmit
        to table 33 to enter the logical egress pipeline.
      </p>
    </li>

    <li>
      <p>
        OpenFlow tables 16 through 31 execute the logical ingress pipeline from
        the <code>Logical_Flow</code> table in the OVN Southbound database.
        These tables are expressed entirely in terms of logical concepts like
        logical ports and logical datapaths.  A big part of
        <code>ovn-controller</code>'s job is to translate them into equivalent
        OpenFlow (in particular it translates the table numbers:
        <code>Logical_Flow</code> tables 0 through 15 become OpenFlow tables 16
        through 31).
      </p>

      <p>
        Most OVN actions have fairly obvious implementations in OpenFlow (with
        OVS extensions), e.g. <code>next;</code> is implemented as
        <code>resubmit</code>, <code><var>field</var> =
        <var>constant</var>;</code> as <code>set_field</code>.  A few are worth
        describing in more detail:
      </p>

      <dl>
        <dt><code>output:</code></dt>
        <dd>
          Implemented by resubmitting the packet to table 32.  If the pipeline
          executes more than one <code>output</code> action, then each one is
          separately resubmitted to table 32.  This can be used to send
          multiple copies of the packet to multiple ports.  (If the packet was
          not modified between the <code>output</code> actions, and some of the
          copies are destined to the same hypervisor, then using a logical
          multicast output port would save bandwidth between hypervisors.)
        </dd>

        <dt><code>get_arp(<var>P</var>, <var>A</var>);</code></dt>
        <dd>
          <p>
            Implemented by storing arguments into OpenFlow fields, then
            resubmitting to table 65, which <code>ovn-controller</code>
            populates with flows generated from the <code>MAC_Binding</code>
            table in the OVN Southbound database.  If there is a match in table
            65, then its actions store the bound MAC in the Ethernet
            destination address field.
          </p>

          <p>
            (The OpenFlow actions save and restore the OpenFlow fields used for
            the arguments, so that the OVN actions do not have to be aware of
            this temporary use.)
          </p>
        </dd>

        <dt><code>put_arp(<var>P</var>, <var>A</var>, <var>E</var>);</code></dt>
        <dd>
          <p>
            Implemented by storing the arguments into OpenFlow fields, then
            outputting a packet to <code>ovn-controller</code>, which updates
            the <code>MAC_Binding</code> table.
          </p>

          <p>
            (The OpenFlow actions save and restore the OpenFlow fields used for
            the arguments, so that the OVN actions do not have to be aware of
            this temporary use.)
          </p>
        </dd>
      </dl>
    </li>

    <li>
      <p>
        OpenFlow tables 32 through 47 implement the <code>output</code> action
        in the logical ingress pipeline.  Specifically, table 32 handles
        packets to remote hypervisors, table 33 handles packets to the local
        hypervisor, and table 34 discards packets whose logical ingress and
        egress port are the same.
      </p>

      <p>
        Logical patch ports are a special case.  Logical patch ports do not
        have a physical location and effectively reside on every hypervisor.
        Thus, flow table 33, for output to ports on the local hypervisor,
        naturally implements output to unicast logical patch ports too.
        However, applying the same logic to a logical patch port that is part
        of a logical multicast group yields packet duplication, because each
        hypervisor that contains a logical port in the multicast group will
        also output the packet to the logical patch port.  Thus, multicast
        groups implement output to logical patch ports in table 32.
      </p>

      <p>
        Each flow in table 32 matches on a logical output port for unicast or
        multicast logical ports that include a logical port on a remote
        hypervisor.  Each flow's actions implement sending a packet to the port
        it matches.  For unicast logical output ports on remote hypervisors,
        the actions set the tunnel key to the correct value, then send the
        packet on the tunnel port to the correct hypervisor.  (When the remote
        hypervisor receives the packet, table 0 there will recognize it as a
        tunneled packet and pass it along to table 33.)  For multicast logical
        output ports, the actions send one copy of the packet to each remote
        hypervisor, in the same way as for unicast destinations.  If a
        multicast group includes a logical port or ports on the local
        hypervisor, then its actions also resubmit to table 33.  Table 32 also
        includes a fallback flow that resubmits to table 33 if there is no
        other match.
      </p>

      <p>
        Flows in table 33 resemble those in table 32 but for logical ports that
        reside locally rather than remotely.  For unicast logical output ports
        on the local hypervisor, the actions just resubmit to table 34.  For
        multicast output ports that include one or more logical ports on the
        local hypervisor, for each such logical port <var>P</var>, the actions
        change the logical output port to <var>P</var>, then resubmit to table
        34.
      </p>

      <p>
        A special case is that when a localnet port exists on the datapath,
        remote port is connected by switching to the localnet port. In this
        case, instead of adding a flow in table 32 to reach the remote port, a
        flow is added in table 33 to switch the logical outport to the localnet
        port, and resubmit to table 33 as if it were unicasted to a logical
        port on the local hypervisor.
      </p>

      <p>
        Table 34 matches and drops packets for which the logical input and
        output ports are the same.  It resubmits other packets to table 48.
      </p>
    </li>

    <li>
      <p>
        OpenFlow tables 48 through 63 execute the logical egress pipeline from
        the <code>Logical_Flow</code> table in the OVN Southbound database.
        The egress pipeline can perform a final stage of validation before
        packet delivery.  Eventually, it may execute an <code>output</code>
        action, which <code>ovn-controller</code> implements by resubmitting to
        table 64.  A packet for which the pipeline never executes
        <code>output</code> is effectively dropped (although it may have been
        transmitted through a tunnel across a physical network).
      </p>

      <p>
        The egress pipeline cannot change the logical output port or cause
        further tunneling.
      </p>
    </li>

    <li>
      <p>
        OpenFlow table 64 performs logical-to-physical translation, the
        opposite of table 0.  It matches the packet's logical egress port.  Its
        actions output the packet to the port attached to the OVN integration
        bridge that represents that logical port.  If the logical egress port
        is a container nested with a VM, then before sending the packet the
        actions push on a VLAN header with an appropriate VLAN ID.
      </p>

      <p>
        If the logical egress port is a logical patch port, then table 64
        outputs to an OVS patch port that represents the logical patch port.
        The packet re-enters the OpenFlow flow table from the OVS patch port's
        peer in table 0, which identifies the logical datapath and logical
        input port based on the OVS patch port's OpenFlow port number.
      </p>
    </li>
  </ol>

  <h2>Life Cycle of a VTEP gateway</h2>

  <p>
    A gateway is a chassis that forwards traffic between the OVN-managed
    part of a logical network and a physical VLAN,  extending a
    tunnel-based logical network into a physical network.
  </p>

  <p>
    The steps below refer often to details of the OVN and VTEP database
    schemas.  Please see <code>ovn-sb</code>(5), <code>ovn-nb</code>(5)
    and <code>vtep</code>(5), respectively, for the full story on these
    databases.
  </p>

  <ol>
    <li>
      A VTEP gateway's life cycle begins with the administrator registering
      the VTEP gateway as a <code>Physical_Switch</code> table entry in the
      <code>VTEP</code> database.  The <code>ovn-controller-vtep</code>
      connected to this VTEP database, will recognize the new VTEP gateway
      and create a new <code>Chassis</code> table entry for it in the
      <code>OVN_Southbound</code> database.
    </li>

    <li>
      The administrator can then create a new <code>Logical_Switch</code>
      table entry, and bind a particular vlan on a VTEP gateway's port to
      any VTEP logical switch.  Once a VTEP logical switch is bound to
      a VTEP gateway, the <code>ovn-controller-vtep</code> will detect
      it and add its name to the <var>vtep_logical_switches</var>
      column of the <code>Chassis</code> table in the <code>
      OVN_Southbound</code> database.  Note, the <var>tunnel_key</var>
      column of VTEP logical switch is not filled at creation.  The
      <code>ovn-controller-vtep</code> will set the column when the
      correponding vtep logical switch is bound to an OVN logical network.
    </li>

    <li>
      Now, the administrator can use the CMS to add a VTEP logical switch
      to the OVN logical network.  To do that, the CMS must first create a
      new <code>Logical_Switch_Port</code> table entry in the <code>
      OVN_Northbound</code> database.  Then, the <var>type</var> column
      of this entry must be set to "vtep".  Next, the <var>
      vtep-logical-switch</var> and <var>vtep-physical-switch</var> keys
      in the <var>options</var> column must also be specified, since
      multiple VTEP gateways can attach to the same VTEP logical switch.
    </li>

    <li>
      The newly created logical port in the <code>OVN_Northbound</code>
      database and its configuration will be passed down to the <code>
      OVN_Southbound</code> database as a new <code>Port_Binding</code>
      table entry.  The <code>ovn-controller-vtep</code> will recognize the
      change and bind the logical port to the corresponding VTEP gateway
      chassis.  Configuration of binding the same VTEP logical switch to
      a different OVN logical networks is not allowed and a warning will be
      generated in the log.
    </li>

    <li>
      Beside binding to the VTEP gateway chassis, the <code>
      ovn-controller-vtep</code> will update the <var>tunnel_key</var>
      column of the VTEP logical switch to the corresponding <code>
      Datapath_Binding</code> table entry's <var>tunnel_key</var> for the
      bound OVN logical network.
    </li>

    <li>
      Next, the <code>ovn-controller-vtep</code> will keep reacting to the
      configuration change in the <code>Port_Binding</code> in the
      <code>OVN_Northbound</code> database, and updating the
      <code>Ucast_Macs_Remote</code> table in the <code>VTEP</code> database.
      This allows the VTEP gateway to understand where to forward the unicast
      traffic coming from the extended external network.
    </li>

    <li>
      Eventually, the VTEP gateway's life cycle ends when the administrator
      unregisters the VTEP gateway from the <code>VTEP</code> database.
      The <code>ovn-controller-vtep</code> will recognize the event and
      remove all related configurations (<code>Chassis</code> table entry
      and port bindings) in the <code>OVN_Southbound</code> database.
    </li>

    <li>
      When the <code>ovn-controller-vtep</code> is terminated, all related
      configurations in the <code>OVN_Southbound</code> database and
      the <code>VTEP</code> database will be cleaned, including
      <code>Chassis</code> table entries for all registered VTEP gateways
      and their port bindings, and all <code>Ucast_Macs_Remote</code> table
      entries and the <code>Logical_Switch</code> tunnel keys.
    </li>
  </ol>

  <h1>Design Decisions</h1>

  <h2>Tunnel Encapsulations</h2>

  <p>
    OVN annotates logical network packets that it sends from one hypervisor to
    another with the following three pieces of metadata, which are encoded in
    an encapsulation-specific fashion:
  </p>

  <ul>
    <li>
      24-bit logical datapath identifier, from the <code>tunnel_key</code>
      column in the OVN Southbound <code>Datapath_Binding</code> table.
    </li>

    <li>
      15-bit logical ingress port identifier.  ID 0 is reserved for internal
      use within OVN.  IDs 1 through 32767, inclusive, may be assigned to
      logical ports (see the <code>tunnel_key</code> column in the OVN
      Southbound <code>Port_Binding</code> table).
    </li>

    <li>
      16-bit logical egress port identifier.  IDs 0 through 32767 have the same
      meaning as for logical ingress ports.  IDs 32768 through 65535,
      inclusive, may be assigned to logical multicast groups (see the
      <code>tunnel_key</code> column in the OVN Southbound
      <code>Multicast_Group</code> table).
    </li>
  </ul>

  <p>
    For hypervisor-to-hypervisor traffic, OVN supports only Geneve and STT
    encapsulations, for the following reasons:
  </p>

  <ul>
    <li>
      Only STT and Geneve support the large amounts of metadata (over 32 bits
      per packet) that OVN uses (as described above).
    </li>

    <li>
      STT and Geneve use randomized UDP or TCP source ports that allows
      efficient distribution among multiple paths in environments that use ECMP
      in their underlay.
    </li>

    <li>
      NICs are available to offload STT and Geneve encapsulation and
      decapsulation.
    </li>
  </ul>

  <p>
    Due to its flexibility, the preferred encapsulation between hypervisors is
    Geneve.  For Geneve encapsulation, OVN transmits the logical datapath
    identifier in the Geneve VNI.

    <!-- Keep the following in sync with ovn/controller/physical.h. -->
    OVN transmits the logical ingress and logical egress ports in a TLV with
    class 0x0102, type 0, and a 32-bit value encoded as follows, from MSB to
    LSB:
  </p>

  <diagram>
    <header name="">
      <bits name="rsv" above="1" below="0" width=".25"/>
      <bits name="ingress port" above="15" width=".75"/>
      <bits name="egress port" above="16" width=".75"/>
    </header>
  </diagram>

  <p>
    Environments whose NICs lack Geneve offload may prefer STT encapsulation
    for performance reasons.  For STT encapsulation, OVN encodes all three
    pieces of logical metadata in the STT 64-bit tunnel ID as follows, from MSB
    to LSB:
  </p>

  <diagram>
    <header name="">
      <bits name="reserved" above="9" below="0" width=".5"/>
      <bits name="ingress port" above="15" width=".75"/>
      <bits name="egress port" above="16" width=".75"/>
      <bits name="datapath" above="24" width="1.25"/>
    </header>
  </diagram>

  <p>
    For connecting to gateways, in addition to Geneve and STT, OVN supports
    VXLAN, because only VXLAN support is common on top-of-rack (ToR) switches.
    Currently, gateways have a feature set that matches the capabilities as
    defined by the VTEP schema, so fewer bits of metadata are necessary.  In
    the future, gateways that do not support encapsulations with large amounts
    of metadata may continue to have a reduced feature set.
  </p>
</manpage>