diff options
Diffstat (limited to 'SDL_Core/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt')
-rw-r--r-- | SDL_Core/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt | 131 |
1 files changed, 0 insertions, 131 deletions
diff --git a/SDL_Core/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt b/SDL_Core/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt deleted file mode 100644 index f11faadfd..000000000 --- a/SDL_Core/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt +++ /dev/null @@ -1,131 +0,0 @@ -/*! \page components_transportmanager_use_cases_3 Scenario with 2 or more devices with 2 or more applications onboard - -<h3>Preconditions:</h3> -<table> - <tr> - <th>Steps</th> - <th>Actions</th> - <th>Expected result</th> - </tr> - <tr> - <td>1</td> - <td>Device-1 is connected to Core via Bluetooth</td> - <td>Devices are paired</td> - </tr> - <tr> - <td>2</td> - <td>Device-2 is connected to SmartDeviceLink Core via Wi-Fi</td> - <td>Devices are in the same network</td> - </tr> - <tr> - <td>3</td> - <td>Make sure that correct devices are connected to SmartDeviceLink core</td> - <td>IP-address of connected devices are relevant</td> - </tr> -</table> - -<h3>Testcase:</h3> -<table> - <tr> - <th>Steps</th> - <th>Actions</th> - <th>Expected result</th> - </tr> - <tr> - <td>1</td> - <td>Start SmartDeviceLink application on the Devices</td> - <td>SmartDeviceLink application is up and ready</td> - </tr> - <tr> - <td>2</td> - <td>Initiate a Device search in HMI</td> - <td>HMI displays the list of found devices/applications</td> - </tr> - <tr> - <td>3</td> - <td>Connect to application-1 on 1-st device</td> - <td>Application is marked as connected/notification is displayed in HMI</td> - </tr> - <tr> - <td>4</td> - <td>Send alert message from SmartDeviceLink application-1 on device-1</td> - <td>Alert is displayed on HMI</td> - </tr> - <tr> - <td>5</td> - <td>Connect to application-2 on 1-st device</td> - <td>Application is marked as connected/notification is displayed in HMI Both applications are marked as connected</td> - </tr> - <tr> - <td>6</td> - <td>Send alert message from SmartDeviceLink application-2 on device-1</td> - <td>Alert is displayed on HMI</td> - </tr> - <tr> - <td>7</td> - <td>Send alert messages from application-1 and application-2 on device-1 simultaneously</td> - <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> - </tr> - <tr> - <td>8</td> - <td>Connect to application-1 on 2-st device</td> - <td>Application is marked as connected/notification is displayed in HMI. All 3 applications are marked as connected</td> - </tr> - <tr> - <td>9</td> - <td>Send alert messages from application-1 on device-1 and device-2 simultaneously</td> - <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> - </tr> - <tr> - <td>10</td> - <td>Send alert message from SmartDeviceLink application-1 on device-2</td> - <td>Alert is displayed on HMI</td> - </tr> - <tr> - <td>11</td> - <td>Connect to application on 2-nd device</td> - <td>Application is marked as connected/notification is displayed in HMI. All 4 applications are marked as connected</td> - </tr> - <tr> - <td>12</td> - <td>Send alert message from SmartDeviceLink application-2 on device-2</td> - <td>Alert is displayed on HMI</td> - </tr> - <tr> - <td>13</td> - <td>Send alert messages from application-1 and application-2 on device-2 simultaneously</td> - <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> - </tr> - <tr> - <td>14</td> - <td>Send alert messages from application-2 on device-1 and device-2 simultaneously</td> - <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> - </tr> - <tr> - <td>15</td> - <td>Send alert messages from all application simultaneously</td> - <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> - </tr> - <tr> - <td>16</td> - <td>Disconnect device-1 from SmartDeviceLink core</td> - <td>Applications are marked as disconnected/notification is displayed in HMI</td> - </tr> - <tr> - <td>17</td> - <td>Disconnect device-2 from SmartDeviceLink core</td> - <td>All applications are marked as disconnected/notification is displayed in HMI</td> - </tr> - <tr> - <td>18</td> - <td><strong>Repeat steps 1-15 with more devices and more applications or use same connection method (BT of Wi-Fi)</strong></td> - <td>Expected results should be the same</td> - </tr> - <tr> - <td>19</td> - <td><h3>Stress:</h3>Send big amount of alert messages in a short period of time from all devices</td> - <td>All alert messages are processed correctly</td> - </tr> -</table> - -*/ |