ovn: Make it possible for CMS to detect when the OVN system is up-to-date.
Until now, there has been no reliable for the CMS (or ovn-nbctl, or anything else) to detect when changes made to the northbound configuration have been passed through to the southbound database or to the hypervisors. This commit adds this feature to the system, by adding sequence numbers to the northbound and southbound databases and adding code in ovn-nbctl, ovn-northd, and ovn-controller to keep those sequence numbers up-to-date. The biggest user-visible change from this commit is new a new option --wait to ovn-nbctl. With --wait=sb, ovn-nbctl now waits for ovn-northd to update the southbound database; with --wait=hv, it waits for the changes to make their way to Open vSwitch on every hypervisor. Signed-off-by: Ben Pfaff <blp@ovn.org> Acked-by: Russell Bryant <russell@ovn.org>
Diffstat (limited to 'ovn/ovn-architecture.7.xml')
-rw-r--r--ovn/ovn-architecture.7.xml74
1 files changed, 74 insertions, 0 deletions
diff --git a/ovn/ovn-architecture.7.xml b/ovn/ovn-architecture.7.xml
index ead4feb71..fe20a14ef 100644
--- a/ovn/ovn-architecture.7.xml
+++ b/ovn/ovn-architecture.7.xml
@@ -200,6 +200,80 @@
+-------------------------------+ +-------------------------------+
</pre>
+ <h2>Information Flow in OVN</h2>
+
+ <p>
+ Configuration data in OVN flows from north to south. The CMS, through its
+ OVN/CMS plugin, passes the logical network configuration to
+ <code>ovn-northd</code> via the northbound database. In turn,
+ <code>ovn-northd</code> compiles the configuration into a lower-level form
+ and passes it to all of the chassis via the southbound database.
+ </p>
+
+ <p>
+ Status information in OVN flows from south to north. OVN currently
+ provides only a few forms of status information. First,
+ <code>ovn-northd</code> populates the <code>up</code> column in the
+ northbound <code>Logical_Switch_Port</code> table: if a logical port's
+ <code>chassis</code> column in the southbound <code>Port_Binding</code>
+ table is nonempty, it sets <code>up</code> to <code>true</code>, otherwise
+ to <code>false</code>. This allows the CMS to detect when a VM's
+ networking has come up.
+ </p>
+
+ <p>
+ Second, OVN provides feedback to the CMS on the realization of its
+ configuration, that is, whether the configuration provided by the CMS has
+ taken effect. This feature requires the CMS to participate in a sequence
+ number protocol, which works the following way:
+ </p>
+
+ <ol>
+ <li>
+ When the CMS updates the configuration in the northbound database, as
+ part of the same transaction, it increments the value of the
+ <code>nb_cfg</code> column in the <code>NB_Global</code> table. (This is
+ only necessary if the CMS wants to know when the configuration has been
+ realized.)
+ </li>
+
+ <li>
+ When <code>ovn-northd</code> updates the southbound database based on a
+ given snapshot of the northbound database, it copies <code>nb_cfg</code>
+ from northbound <code>NB_Global</code> into the southbound database
+ <code>SB_Global</code> table, as part of the same transaction. (Thus, an
+ observer monitoring both databases can determine when the southbound
+ database is caught up with the northbound.)
+ </li>
+
+ <li>
+ After <code>ovn-northd</code> receives confirmation from the southbound
+ database server that its changes have committed, it updates
+ <code>sb_cfg</code> in the northbound <code>NB_Global</code> table to the
+ <code>nb_cfg</code> version that was pushed down. (Thus, the CMS or
+ another observer can determine when the southbound database is caught up
+ without a connection to the southbound database.)
+ </li>
+
+ <li>
+ The <code>ovn-controller</code> process on each chassis receives the
+ updated southbound database, with the updated <code>nb_cfg</code>. This
+ process in turn updates the physical flows installed in the chassis's
+ Open vSwitch instances. When it receives confirmation from Open vSwitch
+ that the physical flows have been updated, it updates <code>nb_cfg</code>
+ in its own <code>Chassis</code> record in the southbound database.
+ </li>
+
+ <li>
+ <code>ovn-northd</code> monitors the <code>nb_cfg</code> column in all of
+ the <code>Chassis</code> records in the southbound database. It keeps
+ track of the minimum value among all the records and copies it into the
+ <code>hv_cfg</code> column in the northbound <code>NB_Global</code>
+ table. (Thus, the CMS or another observer can determine when all of the
+ hypervisors have caught up to the northbound configuration.)
+ </li>
+ </ol>
+
<h2>Chassis Setup</h2>
<p>